B-343 LC MS/MS Measurement of Infliximab, Adalimumab, Ustekinumab, Vedolizumab and Anti Drug Antibodies Using mAbXmise Kits on Xevo TQ Absolute XR MS for Clinical Research
Gareth Hammond, Davor Fielitz, Dorothée Lebert, Lisa Calton, Margaret Guthrie, Michael Wakefield
Key points
From the paper's conclusion- The results support its utility for laboratories conducting analytical characterization, method evaluation, and development of mass spectrometry-based approaches for biologic measurement in clinical research settings.
Abstract
Background Quantitative measurement of therapeutic monoclonal antibodies and antidrug antibodies is valuable for research on inflammation related biologics. Immunoassay based approaches can be affected by matrix interferences and limited multiplexing, motivating peptide level LC MS/MS methods with internal standards for improved analytical specificity and reproducibility. This clinical research study describes a research use only workflow incorporating standardized sample preparation kits and tandem quadrupole mass spectrometry for the measurement of four monoclonal antibodies and two antidrug antibodies. Methods Serum calibrators, quality controls, and research samples were prepared using mAbXmise™ ITDM2 (Multiplex IFX, ADL, USTE, VDZ, etc.) and mAbXmise IADA1 (multiplex anti-IFX and anti-ADL) kits (Promise Proteomics, France) following the manufacturer’s instructions, including overnight digestion at 37°C with the supplied protease. Ten µL of serum were used for monoclonal antibody measurements and 100 µL for antidrug antibody measurements. Chromatographic separation (8 min) used an ACQUITY™ Premier Peptide CSH™ C18 Column on an ACQUITY Premier System. Detection employed multiple reaction monitoring (MRM) on a Waters Xevo™ TQ Absolute XR Tandem Quadrupole Mass Spectrometer. Calibration ranges: 0.5–100 µg/mL for monoclonal antibodies peptides (ITDM2) and 10–400 ng/mL for antidrug antibodies (IADA1). Analytical performance was assessed using multiple QC levels and seven anonymized research samples previously characterized by immunoassay were analyzed to compare analytical behavior between methods. Results All monoclonal antibody peptides demonstrated strong linearity across the evaluated concentration range, 0.5–100 µg/mL, with r² > 0.99; all points met = ±15% deviation criteria. QC based precision was = 10 %RSD with accuracy 94.2–114.2% across levels. For antidrug antibodies, four parameter logistic calibration produced stable fits with LOQs in the ng/mL range; QC precision was = 10 %RSD and accuracy 90.5–105.6%. Analysis of research serum samples demonstrated consistent measurement trends between LC MS/MS and previously generated immunoassay results for both monoclonal antibodies and anti drug antibodies. Samples containing detectable anti drug antibodies by immunoassay showed corresponding peptide signals by LC MS/MS. Observed differences were consistent with expected methodological distinctions. Conclusion This clinical research workflow demonstrates sensitive, specific, and reproducible quantification of monoclonal antibodies and antidrug antibodies using standardized sample preparation and LC-MS/MS detection. The results support its utility for laboratories conducting analytical characterization, method evaluation, and development of mass spectrometry-based approaches for biologic measurement in clinical research settings. For Research Use Only. Not for use in diagnostic procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simultaneous Quantification of Vedolizumab, Ustekinumab, and Infliximab in Human Serum by LC-MS/MS: Application to Therapeutic Drug Monitoring in Inflammatory Bowel Disease.Drug design, development and therapy · 2026
- A Practical Roadmap for Implementing the LC-MS-Based Multi-Attribute Method for Analysis of Therapeutic Proteins.Pharmaceuticals (Basel, Switzerland) · 2026
- Bridging the Gap Between Chemiluminescence Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry for Infliximab Monitoring: Method Validation and Clinical Comparability Study.Journal of separation science · 2026
- Multi-Attribute Methods for Biotherapeutics: A Decade of Evolution.Pharmaceuticals (Basel, Switzerland) · 2026
- Rapid and selective characterization of antibody-drug conjugates in complex sample matrices by native affinity liquid chromatography-mass spectrometrymAbs · 2026
- An automated column-switching LC-MS/MS method using immobilized trypsin for the rapid quantification of pembrolizumab in human serum.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026