B-296 Quantitative Analysis of Creatinine and HbA1c from Dried Microsamples as a Patient Centered Approach for Value Based Care Programs
Ramona Seliger, Jens-Peter Brock, Michelle Wittmann, Mathias Karlsson, Johan Olausson, Mikael Ström
Key points
From the paper's conclusion- Overall, the compatibility of microsamples with standard laboratory chemistry assays provides a potential tool to support simple, patient centered, VBC initiatives aimed at improving early detection and long term management of diabetes.
Abstract
Background Value based care (VBC) programs in the United States increasingly incentivize regular diabetes monitoring, supported by Centers for Medicare & Medicaid Services policies that now cover up to two diabetes screenings per year, including hemoglobin A1c (HbA1c) testing without coinsurance. These measures lower barriers to routine assessment. Clinical guidelines emphasize timely evaluation of HbA1c and kidney function to prevent diabetes related complications. However, traditional venous blood collection can limit access and adherence, especially in rural areas where traveling distances can exceed recommendations for appropriate access and people with impaired mobility. Microsampling solutions for dried blood enables simple, convenient, at home capillary blood collection, reducing the need for clinic visits and improving patient participation. By supporting decentralized, high frequency monitoring, microsampling technology helps providers meet VBC quality metrics related to glycemic control and early detection of kidney disease—key drivers of improved outcomes and reimbursement performance. Methods For creatinine analysis, fresh whole blood from 23 clinical leftover samples was pipetted onto Capitainer B50 Cards and cards were further processed according to the manufacturer’s instructions. Capitainer dried microsamples were subsequently eluted with an 80% methanol solution. Corresponding whole blood control samples were centrifuged to generate plasma. Eluates and liquid control plasma were analyzed with the Atellica CH Enzymatic Creatinine_3 assay. For HbA1c analysis, fresh whole blood from 57 healthy donors was pipetted onto Capitainer B Cards and cards were further processed according to the manufacturer’s instructions. Capitainer dried microsamples were subsequently eluted with HbA1c assay pretreatment solution. Eluates and liquid control whole blood were analyzed with the Atellica CH Enzymatic Hemoglobin A1c assay. For both assays, the instrument pipetting schemes were adapted to consider the dilution factor introduced by microsample elution. Results Creatinine concentrations measured from the microsamples show a linear association with the corresponding liquid control concentrations (R²=0.99). The absolute concentrations are approximately 65% lower compared to the liquid controls. Methanol at the concentration used does not significantly affect assay performance. HbA1c values in percentage show a linear association with the liquid control values as well (R²=0.85). Stability studies indicate a storage time–dependent increase in HbA1c values. For both analytes, the mean coefficient of variation between duplicates from one sample is below 1.5%. Conclusion Capitainer microsampling demonstrates strong potential as a practical alternative to conventional venous blood collection for HbA1c and creatinine measurement in decentralized or remote monitoring settings. Although the eluted microsamples results yield lower absolute concentrations than liquid controls due to dilution and partial recovery effects, the linear association between matrices supports reliable quantification. For creatinine, the resulting lower limit of quantification remains below the relevant physiological ranges. The HbA1c results remain unaffected as it is reported as a percentage rather than an absolute concentration. But the revealed finding of the storage related increases in HbA1c emphasizes the need for proper control of the workflow. Overall, the compatibility of microsamples with standard laboratory chemistry assays provides a potential tool to support simple, patient centered, VBC initiatives aimed at improving early detection and long term management of diabetes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-373 Creatinine Measurement Using the Dried Blood Microsampling Device Capitainer®B50: Analytical Validation, Correction Modeling, and Stability EvaluationClinical Chemistry · 2026
- A-372 Assessment of Urinary Albumin to Creatinine Ratio Using the Capitainer Dip70® Dried Urine Microsampling Device on Automated Clinical AnalyzersClinical Chemistry · 2026
- Optimized Hemoglobin Depletion Improves Clinical Proteomics from Dried Blood Spots.Journal of proteome research · 2026
- The utility of point-of-care haemoglobin A1c tests in a very remote Aboriginal and Torres Strait Islander community: an agreement analysis with routine laboratory testing.Rural and remote health · 2026
- Capillary blood sampling in neurodegenerative diseases - the future for screening and monitoring brain health?Expert review of neurotherapeutics · 2026
- Mobile point-of-care testing to improve access to care for people experiencing homelessness and diabetes in Los Angeles.American journal of clinical pathology · 2026