B-232 Concordance Between Alzheimer’s Disease CSF and Plasma Biomarker Assays

Susan Ashrafzadeh-Kian, Danting Liu, Sarah Zilka, Joshua Bornhorst, Jessica Colon-Franco, Alicia Algeciras-Schimnich

Key points

From the paper's conclusion
  • These findings highlight the importance of clinical context interpretation of elevated plasma p-tau217 results.

Abstract

Background Plasma p-tau217 assays are clinically valuable tools for evaluation of Alzheimer’s Disease (AD) pathology. Discrepancy between plasma p-tau217 and cerebrospinal fluid (CSF) biomarkers (Aß42/40 and p-tau181/Aß42), however, may present an interpretive challenge for clinicians. Two plasma p-tau217 assays (Roche Diagnostics and Fujirebio Lumipulse) were evaluated to assess the frequency of discordant results versus CSF AD biomarkers. Methods The study cohort consisted of 65 paired CSF and EDTA plasma residual patient samples with plasma p-tau217 and CSF AD biomarkers ordered 0.028, CSF Aß42/40?<0.073, Elecsys p-tau217 >0.249 (Youden), and Lumipulse p-tau217 >0.229 (Youden). Creatinine eGFR (mL/min/1.73m2) was calculated using the CKD-EPI 2021 equation. CSF assays were either used individually or considered concordant and used as the reference standard for amyloid positivity. The McNemar test was performed to determine if differences in CSF concordance with plasma assays were statistically significant. Results CSF p-tau181/Aß42?and CSF Aß42/40 were concordant in 91% of cases, whereas plasma p-tau217 assays were concordant with each other in 76% of cases. Overall discordance between plasma Lumipulse p-tau217 and CSF classification was 22% for p-tau181/Aß42?and 25% for Aß42/40. Discordance between plasma Elecsys p-tau217 and the CSF classification was 34% for p-tau181/Aß42?and 31% for Aß42/40. No statistically significant difference in concordance between the CSF and plasma biomarkers were observed between either of the two CSF assays versus the Elecsys plasma p-tau 217 (p=0.69) or for Lumipulse plasma p-tau217(p=0.69). When considering samples in which both CSF assays were concordant (N=59), there were 22% FP and 8% FN results against plasma Elecsys p-tau217 and 12% FP and 8% FN against Lumipulse plasma p-tau217 (see Table 1). Chronic kidney disease (CKD) was examined as a potential contributor to discordance between plasma and CSF determinations. Of the 59 CSF-concordant samples, 31% (4/13) of the false positive plasma p-tau217 results had an eGFR of <60 for the Elecsys p-tau217 assay, and 29% (2/7) had an eGFR of <60 for the Lumipulse p-tau217 assay. Comparatively, in the remainder of the cohort (TP, TN, and FN), 13% (6/46) and 15% (8/52) of samples for the Elecsys and Lumipulse p-tau217 assays, respectively, had an eGFR <60. Conclusion CSF AD biomarkers demonstrated high concordance (91%), whereas plasma p tau217 assays were concordant in only 76% of cases. Both p-tau217 plasma assays produced FP and FN results, with the Roche Elecsys assay exhibiting a higher frequency of false positives (22%) compared with the Lumipulse assay (12%). In both plasma assays, a portion of FP results occurred in individuals with reduced kidney function (eGFR <60), indicating that CKD may contribute to elevated plasma p-tau217 in some, but not all cases of discrepant CSF and plasma p-tau217 results. These findings highlight the importance of clinical context interpretation of elevated plasma p-tau217 results.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers