A-320 Verification of hemolysis levels to improve laboratory workflow

Emily Smith, Cierra Sharp

Key points

From the paper's conclusion
  • Conclusion We revised our hemolysis workflow based on updated hemolysis levels.

Abstract

Background Hemolyzed samples are often rejected by the Clinical Laboratory since hemolysis can lead to misinterpretation of laboratory results with adverse clinical outcomes. When a sample is hemolyzed, the common workflow is to redraw and retest, leading to an increased workload for staff, delayed turnaround time, and prolonged length of stay for patients. Previously, we developed a hemolysis workflow to decrease the number of redraws and retests. Hemolyzed samples require the Laboratory to follow up with a Provider to determine if results can be released or if the sample should be re-drawn. If the Provider asks that results be released, a comment is added to the LIS result to document approval of release. After implementation, it was found that all analytes would flag in the LIS with a hemoglobin concentration of 300 mg/dL even though many analytes are not significantly affected by hemolysis at this level. This created additional work for the Laboratory staff who would then review the hemolysis level listed in the procedure before verifying results. Our goals were to (1) verify accuracy of hemolysis (hemoglobin) measurement on the Alinity C as proof of principle, (2) perform in-house studies to verify manufacturer-provided hemolysis levels, and (3) update hemolysis flags in our LIS to align with in-house studies and manufacturer IFU. Methods Stock hemolysate was made using a Lithium Heparin whole blood sample. To induce hemolysis, the sample was frozen at -30°C for one hour and then thawed. The stock hemolysate was then analyzed on the Alinity C and the Hemocue to obtain the initial hemoglobin concentration. Twenty plasma samples were pooled together and analyzed for 29 analytes to obtain baseline values. Hemolysate was then diluted with the pooled sample to obtain varying concentrations of hemoglobin. Finally, each pool was analyzed for the effect of hemolysis on each analyte. Results Hemocue and Alinity C hemoglobin measurement correlated (slope: 0.95; R^2=0.9998), allowing us to continue with our hemolysis studies. The following analytes were found to be affected by hemolysis at a level lower than what was listed in the manufacturer IFU: ALT, Amylase, AST, Creatinine, and Direct Bilirubin. 55% of analytes tested had an incorrect hemolysis level listed in the LIS. A report was pulled for a two-month period to assess frequency of hemolyzed samples. The overall frequency of hemolyzed samples based on current criteria was 0.007% and, when re-categorized based on updated information, was 0.006%. Eleven samples that were previously not flagged as hemolyzed were found to be hemolyzed based on updated criteria. Conclusion We revised our hemolysis workflow based on updated hemolysis levels. In our system, overall hemolysis rates are low and there was minimal change in rate after reviewing against updated hemolysis criteria. However, there was a 59% reduction in the number of analytes that require Provider approval to release results at a hemolysis level =300 mg/dL, saving time laboratory staff must spend discussing results and documenting in the LIS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-320 Verification of hemolysis levels to improve laboratory workflow — Science Skim