A-318 IMPROVEMENT OF PREANALYTICAL WORKFLOW WITH THE USE OF PRE-BARCODED TUBES
Ana-Maria Simundic, Giuseppe Lippi, Ann Verdonk, Henk Ruven, S N E Z A N A JOVICIC
Key points
From the paper's conclusion- During the transition, 60% (21/35) faced personnel resistance, mainly due to workflow changes (71.4%, 15/21) and digital solution challenges (42.8%, 9/21).
Abstract
Background Preanalytical errors account for roughly 60–70% of laboratory mistakes, with specimen labeling representing a major source of patient misidentification. Common issues include mislabeled, partially labeled, unlabeled, and illegible specimens. Pre-barcoded tubes (PBTs) meet these challenges by assigning a unique identification code at manufacture, which integrates with digital systems to automate specimen tracking and minimize manual labeling errors. PBT’s and its supportive digital systems strengthen the connection between patient and sample data, enhancing preanalytical reliability. This study aimed to evaluate how implementing PBTs affects preanalytical workflow and the frequency of sample misidentification errors in clinical laboratories. Methods An anonymous online survey was conducted using Microsoft Forms and distributed on 12/01/2024 to 58 medical laboratories that routinely use PBTs. The survey included 25 questions covering laboratory type, departmental structure, digital solutions, daily PBT turnover, SOPs for sample identification and error monitoring, tracking of preanalytical errors, misidentification rates before and after PBT introduction, impacts on turnaround time (TAT) and staffing (FTEs), duration required for PBT adoption, and personnel response to the transition. Laboratories were asked to respond by 12/31/2024. Responses were summarized in counts and percentages using Microsoft Excel. Binary question significance was analyzed with the exact binomial test; chi-square goodness-of-fit tests were used for questions with three categories, and chi-square tests of proportions compared individual proportions. Statistical analyses were completed using MedCalc©, version 23.2.8, with a two-sided p-value <0.05 considered statistically significant. Results Forty-four laboratories participated, and 79.5% (35/44) were using PBTs. Over half (20/35) processed up to 5,000 PBTs daily. Among PBT users, 80% (28/35) monitored sample identification errors, out of which 43% (12/28) compared to pre- and post-implementation misidentification rates. The introduction of PBTs resulted in annual misidentification rates dropping below 10% across all respondents. A significant majority, 80% (24/30) (95% CI: 61.4–92.3%, ?²=3.286, p<0.0001), of the respondents to the respective question indicated that the introduction of PBT led to a substantial reduction in turnaround time (TAT). Most (63%, 15/24) saved 1–3 hours daily in processing per employee involved in preanalytical activities. Other benefits included shorter blood collection times, reduced FTE staffing needs, and fewer laboratory errors (?²=8.690, df=2, p=0.0013). During the transition, 60% (21/35) faced personnel resistance, mainly due to workflow changes (71.4%, 15/21) and digital solution challenges (42.8%, 9/21). However, no single reason for resistance was statistically predominant (?²=7.790, df=5, p=0.1682). Despite these hurdles, more than half (51.4%, 18/35) adopted PBTs within one month. The most frequent positive outcome was time savings (60%, 21/35), followed by improved labeling safety (26%, 9/35) and reliability of electronic barcoding (26%, 9/35). Conclusion Statistical analysis confirmed that PBT implementation led to marked improvements in sample identification accuracy, processing efficiency, and workflow reliability. Time savings and enhanced labeling safety emerged as the most significant advantages.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- How do pre-barcoded tubes improve preanalytical workflow? A survey study.Clinical chemistry and laboratory medicine · 2026
- A-310 Improving CPOE Barcode Readability in the Emergency Department to Reduce Laboratory Reprinting: A Multidisciplinary Quality Improvement InitiativeClinical Chemistry · 2026
- Pre-analytical errors in a high-volume Bangladeshi diagnostic centre: Prevalence, workload impact, and mitigation strategiesPLoS ONE · 2026
- TraceLab: Twelve Months of Real-World Digital Traceability for Biological Samples at a Chilean Clinical Research Center.Biopreservation and biobanking · 2026
- B-038 Design and standardization of automated pre-analytical and post-analytical workflows to support growth in a high-volume clinical laboratoryClinical Chemistry · 2026
- A-356 Survey of Preanalytical Errors in Blood Gas Sample Collection and Analysis: Frequency, Impact, and Improvement Priorities Across U.S. Healthcare SettingsClinical Chemistry · 2026