Clinical Chemistry

A-310 Improving CPOE Barcode Readability in the Emergency Department to Reduce Laboratory Reprinting: A Multidisciplinary Quality Improvement Initiative

Siew-Kim Ong

Key points

From the paper's conclusion
  • Conclusion A multidisciplinary quality improvement approach successfully reduced CPOE barcode reprinting by 50%, resulting in time and cost savings while maintaining laboratory turnaround times.

Abstract

Background The laboratory receives specimens labeled with Computerized Physician Order Entry (CPOE) linear barcodes. A proportion of these labels are unreadable by laboratory analyzers due to poor print quality or improper label application, resulting in barcode reprinting. Reprinting delays electronic health record (EHR) reporting and increases the risk of specimen mislabeling. An interdepartmental team was formed to reduce barcode reprinting at the laboratory specimen reception station by 50%. Methods From May 2023 to October 2024, barcode reprint data were collected periodically over three-day sampling periods, with average reprints per 8-hour shift calculated. Root cause analysis using the 5 Whys methodology guided targeted interventions addressing both staff- and printer-related factors. Results Of reprinted barcodes, 55% originated from the Emergency Department (ED) 36% from inpatient wards, and 9% from outpatient clinics. The average number of reprinted barcodes per 8-hour shift decreased from 103 in May 2023 to 46 in October 2024, achieving the 50% reduction target after an extended project duration. Root cause analysis identified staff-related factors in 78% of cases and printer-related factors in 22%. Interventions included staff education on correct barcode placement a guide sent out as mass emails and its placement in Hospital Docupedia for easy access, training video incorporated into clinical orientation programs, hands-on nursing education aids on analyzer racks with tubes, trials of alternative barcode label suppliers in ED, improved reporting of printer issues to IT by laboratory staff for rapid response, and 126 hospital-wide visual reminders as posters (Picture 1). Conclusion A multidisciplinary quality improvement approach successfully reduced CPOE barcode reprinting by 50%, resulting in time and cost savings while maintaining laboratory turnaround times. Continued monitoring is planned to assess long-term sustainability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers