A-315 Monoclonal protein test utilization and guideline adherence in a large national reference laboratory dataset
Pratistha Ranjitkar, Sarah Lee, Jill Pauli, Bhrugu Yagnik
Key points
From the paper's conclusion- These findings identify an opportunity for targeted educational and ordering interventions to help improve guideline adherence and potentially support earlier and more complete evaluation of suspected plasma cell disorders.
Abstract
Background While clinical and laboratory guidelines recommend combined serum protein electrophoresis (SPE), and serum free light chain (sFLC) testing for the initial evaluation of suspected monoclonal gammopathies for optimal sensitivity, incomplete or non–guideline-adherent testing has been recognized as a concern in real-world practice. Monoclonal protein testing patterns have not been well characterized at a national level, limiting understanding of guideline adherence and opportunities for improvement across ordering specialties. This study uses data from a national reference laboratory to examine overall ordering trends and test utilization within certain specialties. IC10 diagnosis codes were used to gain further insights into ordering practices for clinical indications including screening or monitoring. Methods Labcorp’s testing database was queried for SPE orders from 2022-2024 (N > 1.8, million samples annually) along with sFLC tests and immunofixation (IFE) ordered a la carte or as part of panel testing. SPE or SPE/IFE ordered with sFLC were considered guideline consistent. If a sFLC was not ordered with SPE or SPE/IFE, the order was considered incomplete. Only SPE testing orders from hematology (HE), oncology(On), neurology(N), nephrology(NEP), primary care(PC), and rheumatology(RHU) provider specialties were included in this study. Using top 20 most frequently appearing ICD10 codes SPE testing orders were parsed by clinical indication for exploratory ICD-10 codes associated with signs and symptoms of multiple myeloma (MM) and for ICD-10 codes associated with monoclonal gammopathy (MG) monitoring. ICD-10 codes for signs and symptoms of MM included codes included anemia (D64.9, D63.1, D69.6), thrombocytopenia (D69.6), renal impairment (N18.30, N18.31, N18.32), hypercalcemia (E83.52), other nonspecific symptoms that raise clinical suspicion for MM (R80.9, R53.83, M25.50, R20.2, R79.89, G62.9). ICD-10 codes for MG monitoring codes included C90.00, C90.01, C90.02 and D47.2 Results 54.3% of SPE testing orders in the Labcorp testing database from selected specialties did not include sFLC tests, demonstrating a gap in guideline-consistent testing. Panels with all 3 tests were largely underutilized (12.6%), and 33.1% of sFLC orders came in as a la carte orders. In each sub-specialty the following percentage of orders were guideline-consistent: HE:78.3%; ON:76.3%; N:12.3%; NEP:48.1%; PC:25.3%; and RHU:10.5%. In the test group representing incomplete orders, 44.8% had exploratory ICD10 codes compared to 33.9% of guideline-consistent orders; p<0.001). In guideline-consistent orders 47.1% of orders were associated with MG diagnosis codes vs. 8.3% in incomplete orders; p<0.001). Conclusion Monoclonal protein testing in real-world practice is highly heterogeneous, with substantial underutilization of guideline-consistent sFLC testing, particularly in non-hematology specialties and exploratory diagnostic settings. These findings identify an opportunity for targeted educational and ordering interventions to help improve guideline adherence and potentially support earlier and more complete evaluation of suspected plasma cell disorders.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-189 Comparative Analysis of Free Light Chain Assay and Electrophoretic Techniques in the Laboratory Assessment of Monoclonal AbnormalitiesClinical Chemistry · 2026
- 24 Unintended Consequences of Screening for Paraproteinemic Neuropathy With Standalone ImmunotypingAmerican Journal of Clinical Pathology · 2026
- Consistency and correlation of a domestic Kehua serum free light chain assay with two imported analytical systems.Frontiers in oncology · 2026
- B-039 Harmonizing M-protein analysis: an international, multi-center reproducibility study of the EXENT® System and evaluation of concordance to electrophoretic methodsClinical Chemistry · 2026
- B-137 Diazyme and Freelite Serum Free Light Chain Assays Are Not Clinically Interchangeable at IMWG-Defined Decision PointsClinical Chemistry · 2026
- B-113 Comparison of Immunofixation Gel Methods and Immunotyping for Monoclonal Protein CharacterizationClinical Chemistry · 2026