A-230 Establishing an Optimal HIT Optical Density Value: A Six Year Study
Cate Hoesl, Atef Shrit, Paul Riley, Joffrey Feriel
Key points
From the paper's conclusion- We validated an optimal HIT OD value for our providers that correlated with a positive HIT confirmatory assay result.
Abstract
Background Our core laboratory provides Heparin Induced Thrombocytopenia antibody (HIT) laboratory screening to patients across our health system. Our enzyme-linked immunosorbent assay (ELISA) format can be reported using a Positive or Negative result and in raw optical density (OD) units. We validated an optimal HIT OD value for our providers that correlated with a positive HIT confirmatory assay result. Reporting the HIT OD value can bring greater confidence to clinicians, since a high HIT OD value strongly correlates to positive HIT confirmatory value by serotonin release assay (SRA), especially if the patient’s clinical score (i.e. 4Ts Score) is intermediate or high. Methods A polyspecific (IgG, IgM, IgA) HIT test using ELISA methodology was used for HIT screening (Asserachrom HPIA, Diagnostica Stago, Inc., Parsippany NJ, USA). HIT OD values were determined using a a VersaMax Microplate reader at a wavelength of 450 nm. Six years of positive HIT OD patient data was analyzed for mean average OD value, distribution of the OD values across the positive reportable range, and correlation with Serotonin Release Assay (SRA) results. ROC data analysis was performed for determination of the optimal HIT OD cutoff correlating with positive confirmatory SRA result. Results We determined a HIT OD of 1.281 with an optimal sensitivity of 85.7% and specificity of 82.7%. Conclusion A HIT OD value was determined with peak sensitivity and specificity versus a positive SRA value. Since SRA testing often takes days to complete at an outside reference laboratory, having an optimal HIT OD value can better predict a positive SRA result and can help diagnose HIT with a faster turnaround time, allowing for better patient management and therefore potential improved patient outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of heparin on immunological heparin-induced thrombocytopenia-IgG chemiluminescence testing.Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis · 2026
- Performance evaluation of a reflexive algorithm for suspected heparin-induced thrombocytopenia.Research and practice in thrombosis and haemostasis · 2026
- A buffer-positive serotonin release assay pattern is associated with increased mortality in HIT: a retrospective cohort study.Research and practice in thrombosis and haemostasis · 2026
- Clinical pharmacist-guided management of heparin-induced thrombocytopenia with thrombosis after hip hemiarthroplasty: a case reportFrontiers in Cardiovascular Medicine · 2026
- Ticagrelor-Induced False-Negative Serotonin Release Assay in Heparin-Induced Thrombocytopenia With Stent ThrombosisJACC Case Reports · 2026
- Saline whole-blood impedance aggregometry for detection of heparin-independent platelet-activating anti-platelet factor 4 antibodies.American journal of clinical pathology · 2026