A buffer-positive serotonin release assay pattern is associated with increased mortality in HIT: a retrospective cohort study.
Tarinee Rungjirajittranon, Theodore E Warkentin, Adam Cuker
Division of Hematology, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. · Department of Pathology and Molecular Medicine, Department of Medicine, and McMaster Centre for Transfusion Research, Michael G. DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada.
Key points
From the paper's conclusion- Among patients with HIT, a buffer-positive SRA pattern was associated with more prolonged thrombocytopenia and increased mortality. Given that our assay used platelet-rich plasma, these findings are hypothesis-generating and require confirmation with the classical washed-platelet SRA.
Abstract
BACKGROUND: HIT is an anti-platelet factor 4 (PF4) disorder characterized by thrombocytopenia and increased thrombosis risk. The serotonin release assay (SRA) is the gold standard test for diagnosing HIT. The clinical significance of a buffer-positive SRA pattern remains uncertain. OBJECTIVES: This study compared characteristics and outcomes between patients with HIT with buffer-negative and buffer-positive SRA patterns. METHODS: We conducted a retrospective cohort study at the Hospital of the University of Pennsylvania and affiliated hospitals. Consecutive patients with confirmed HIT, defined as a positive PF4/heparin enzyme-linked immunoassay and platelet-rich plasma-based SRA without a high-heparin inhibition step, were classified by an SRA pattern (buffer-negative vs buffer-positive) and followed for 30 days. The primary outcome was cumulative incidence of thrombosis; secondary outcomes included mortality, major bleeding, and platelet recovery. RESULTS: Of 207 HIT-positive patients, 190 (91.8%) had a buffer-negative and 17 (8.2%) had a buffer-positive SRA pattern. Median anti-PF4/heparin enzyme-linked immunoassay optical density was significantly lower in the buffer-positive group (0.8 vs 2.3; P < .001). Thrombosis incidence was similar between groups (64.7% vs 50.2%; P = .28). The buffer-positive pattern was independently associated with longer time to platelet recovery (9.0 vs 5.0 days; P = .03) and higher 30-day cumulative incidence of death (47.4% vs 17.1%; adjusted hazard ratio, 2.74; P = .03). CONCLUSION: Among patients with HIT, a buffer-positive SRA pattern was associated with more prolonged thrombocytopenia and increased mortality. Given that our assay used platelet-rich plasma, these findings are hypothesis-generating and require confirmation with the classical washed-platelet SRA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Saline whole-blood impedance aggregometry for detection of heparin-independent platelet-activating anti-platelet factor 4 antibodies.American journal of clinical pathology · 2026
- Ticagrelor-Induced False-Negative Serotonin Release Assay in Heparin-Induced Thrombocytopenia With Stent ThrombosisJACC Case Reports · 2026
- A-230 Establishing an Optimal HIT Optical Density Value: A Six Year StudyClinical Chemistry · 2026
- Effect of heparin on immunological heparin-induced thrombocytopenia-IgG chemiluminescence testing.Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis · 2026
- Clinical pharmacist-guided management of heparin-induced thrombocytopenia with thrombosis after hip hemiarthroplasty: a case reportFrontiers in Cardiovascular Medicine · 2026
- The hepatic FGFR-ERK-HRG axis regulates heparin-induced thrombocytopenia with thrombosis.Blood · 2026