Clinical Chemistry

A-219 Risk-Based Ranking of Microscopists in Manual Leukocyte Differentials: A Personalized FMEA Linking Precision, Trueness, and Accuracy Indices to Rumke Interval Nonconformities

Cyra Araujo, Saulo Valente, Pillar Sartori, Samya Paiva, Silvane Moraes, Thiago Fernandes, Wellington Dourado, Renata Lima e Silva,

Key points

From the paper's conclusion
  • Using 200-leukocyte differentials provides a more stable basis for performance discrimination than 100-leukocyte counts.

Abstract

Introduction Rumke limits are widely used to judge acceptability of manual leukocyte differential counts, but they do not rank microscopist performance or integrate precision, trueness (bias), and accuracy into a single, actionable prioritization scheme. As a consequence, laboratories often lack an objective way to decide which microscopists and which cell types should be targeted first to improve inter-observer harmonization. This study aimed to develop and apply an Excel-based, personalized, multi-criteria FMEA to quantify and rank microscopist performance and to guide harmonization by combining agreement, reproducibility, bias, extreme errors, and Rumke-based nonconformities. Methods Eight experienced microscopists evaluated 20 peripheral blood smears. For each smear, both 100- and 200-leukocyte differentials were performed (segmented neutrophils, lymphocytes, eosinophils, monocytes, basophils). For each smear and cell type, the tool defined a target from group readings (mode when repeated values occurred; otherwise, median) and computed Rumke acceptability limits for a 200-cell differential to classify nonconformities. A reduced FMEA generated a Risk Score per microscopist and cell type as R = G × O. Global Severity (G) combined: (i) agreement to the target using Lin’s concordance correlation coefficient (?c); (ii) reproducibility across smears using the Amplitude Index (IA); (iii) mean trueness using the Systematic Error Index (IES), defined as mean bias normalized to a laboratory-defined maximum allowable systematic error; and (iv) worst-case performance using the Total Error Index (IET), defined as the mean of the largest deviations (top 20%) normalized to a Rumke-derived tolerance. Global Occurrence (O) combined: (i) short-term sigma (Sigma_ST) derived from the proportion of results outside Rumke limits and (ii) compliance with a minimum concordance target (default 80%, configurable), with punitive weighting when unmet. Component scoring rules and weights were user-configurable to reflect hematology practice and local quality goals. Risk Scores were used for microscopist ranking, Pareto prioritization, and ABC stratification (Nihen index) to define high-, medium-, and low-priority targets for harmonization. Results The multi-criteria FMEA produced an interpretable and reproducible ranking of microscopists and cell types by jointly capturing agreement, systematic bias, and extreme deviations, while incorporating the frequency of Rumke nonconformities. Risk contributions were concentrated in a subset of microscopist–cell-type combinations, supporting Pareto/ABC prioritization for targeted standardization and training. When the same scoring framework was applied to 100-cell versus 200-cell differentials, 100-cell counts yielded markedly greater dispersion of Risk Scores between microscopists, indicating lower stability of performance discrimination at reduced counting depth. In contrast, 200-cell counts produced more stable criticality estimates and reduced between-microscopist variability, supporting their operational use when the goal is harmonization assessment rather than rapid screening. Conclusion An Excel-based, personalized FMEA can extend Rumke-based evaluation into a structured decision-support tool that quantifies and ranks microscopist criticality, prioritizes targets for standardization, and supports monitoring of harmonization over time. The tool has been implemented in routine practice to guide corrective actions, follow trends, and document improvement. Using 200-leukocyte differentials provides a more stable basis for performance discrimination than 100-leukocyte counts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers