A-190 Comparison of a semi-automated serum Creatinine measurement method using a novel comprehensive graphical tool based on Bland-Altman plot overlayed with pre-defined tolerance and regression-based reportable limits
Sudip Datta, Saumya Srivastava
Key points
From the paper's conclusion- This study describes the development of a novel graphical Bland-Altman validation tool that integrates regression analysis, confidence intervals, and piecewise tolerance limits to provide a rigorous assessment of method performance and demonstrates its application to validate a candidate method for serum creatinine measurement against a reference method.
Abstract
Background Standard method comparison techniques, such as simple correlation coefficients or Bland-Altman (BA) plots, often fail to fully characterize the clinical acceptability of a new measurement method. They may obscure range-specific biases or fail to contextually evaluate errors against clinical performance goals, which are often guided by the intended use of the device. To ensure a new measurement method meets rigorous clinical requirements across its entire reportable range, a more dynamic evaluation tool is required. This study describes the development of a novel graphical Bland-Altman validation tool that integrates regression analysis, confidence intervals, and piecewise tolerance limits to provide a rigorous assessment of method performance and demonstrates its application to validate a candidate method for serum creatinine measurement against a reference method. Methods A method comparison study was conducted using serum creatinine data (N=165) ranging from 0.24 mg/dL to 6.2 mg/dL, comparing a candidate method (Creat_M) against a reference method (Creat_A). The analysis framework was built upon the Bland-Altman difference plot which was customized by the following steps: (i) overlaying Ordinary Least Squares (OLS) regression of the differences to investigate proportional bias, if any. (ii) 95% Confidence Intervals (95% CI) of the regression line was overlayed to account for sampling uncertainty. (iii) Piecewise Clinical Tolerance Limits were defined and drawn at ±0.15 mg/dL for concentrations =1.0 mg/dL and at ±15% of for concentrations >1.0 mg/dL as per CLIA guidelines according to the intended use. (iv) Vertical dashed lines were overlayed to mark the points where the 95% CI of the regression line intersects with the tolerance limits to represent the valid reportable limits. Results The traditional BA plots revealed a mean difference -0.04mg/dL (95% CI: -0.10, 0.02) which does not demonstrate a significant bias and concealed a significant downward trend in bias. On overlaying OLS regression, Creat_M demonstrated a proportional slope of approximately 0.82 and a positive intercept of 0.23, indicating it over-estimates at low concentrations and under-estimates at high concentrations. The validation tool identified that the method’s error profile remained within clinical tolerance limits only between 0.68 mg/dL and 4.36 mg/dL. Below 0.68 mg/dL, the method exceeded the upper absolute tolerance limit, and above 4.36 mg/dL, the method’s negative bias caused it to breach the lower proportional tolerance limit. Within this reportable range there were 93 data points out of which 26 (27.9%) were outliers, 17 (65.4%) of them being overestimations and 9 (34.6%) being underestimations. (Figure 1) Conclusion The comprehensive graphical tool successfully defined the analytical range (0.68 – 4.36 mg/dL) where the Creat_M values are valid. Within the reportable range this novel method defined the proportion of outliers beyond the tolerance limits. It also successfully classified the proportion of overestimations versus underestimations amongst the outliers. Thereby, the comprehensive method evaluation statistics helps us to define the suitability of Creat_M for its intended use of community-based screening where overestimation may increase the specificity. This approach provides a comprehensive, rigorous, visual, and quantitative framework for defining agreement between two methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-284 Validation of Cystatin C on Abbott Alinity CClinical Chemistry · 2026
- A-411 Evaluation of Point-of-Care Creatinine Analyzers: eGFR Categorization Accuracy for Safe Contrast AdministrationClinical Chemistry · 2026
- Methods for Adjusting for Covariate Measurement Error in Flexible Modeling of Functional Form: Designing a Blinded, Controlled Neutral Comparison Simulation Study.Biometrical journal. Biometrische Zeitschrift · 2026
- What the mean absolute percentage error (MAPE) should adopt from Bland–Altman analysesGerman Journal of Exercise and Sport Research · 2025
- Urinary creatinine estimation as an important analytical limitation of semi-quantitative albumin-to-creatinine ratio strip testing: a diagnostic accuracy study.Frontiers in medical technology · 2026
- Strengthening the interpretation of longitudinal EQA data through the sporadic inclusion of native human sera in general clinical chemistry.Frontiers in molecular biosciences · 2026