A-185 Time-Dependent Stability of Urinary Myoglobin: Effects of pH and Storage Temperature in Routine Clinical Specimens
Sunhyun Ahn, Sanggon Lee, Hojoong Kim, Joonho Choi, Eunhee Lee
Key points
From the paper's conclusion- These findings emphasize the importance of immediate urine pH adjustment and standardized pre-analytical handling to ensure reliable urinary myoglobin measurement in routine clinical laboratory practice.
Abstract
Background Urinary myoglobin measurement is clinically relevant for the evaluation of rhabdomyolysis and for assessing the risk of acute kidney injury. However, the analytical reliability of urinary myoglobin testing is frequently compromised by pre-analytical instability. Urine is a highly variable biological matrix, and myoglobin is known to be particularly unstable under acidic conditions. Most previous studies have focused on short observation periods and have relied on delayed reference points rather than baseline concentrations. Moreover, systematic comparisons between refrigerated and frozen storage under identical pH conditions over extended storage periods remain limited. Methods Residual urine specimens submitted to GC Labs for routine clinical testing were used after completion of analysis. Pooled urine was prepared, and human myoglobin exceeding 130,000 ng/mL was spiked to achieve a baseline concentration of approximately 2,800 ng/mL. Urine pH was adjusted to 5, 6, 7, 8, and 9 using 10% sodium carbonate solution, and pH was measured using Sysmex Meditape UC-9A. Aliquots were stored under refrigerated (4 °C) or frozen (–20 °C) conditions. Urinary myoglobin concentrations were measured at baseline, serially up to 24 hours, and subsequently on days 2–5 using the Roche cobas Elecsys Myoglobin immunoassay. Stability was assessed as percentage recovery relative to baseline. Results Urinary myoglobin demonstrated marked pH-dependent degradation. At pH 5, concentrations declined rapidly within the first 24 hours to approximately 20- 25% during refrigerated storage (2805544 ng/mL) and frozen storage (2805725 ng/mL). Continued storage resulted in further substantial loss, with concentrations decreasing to <10% of baseline under refrigerated conditions (2805187 ng/mL) and remaining at approximately 25% under frozen conditions (2805734 ng/mL) by day 5. At pH 6, degradation was less pronounced but remained clinically meaningful: approximately 70–75% of baseline was retained at 24 hours (refrigerated: 28052117 ng/mL; frozen: 28052025 ng/mL), followed by progressive declines to approximately 40% during refrigerated storage (28051202 ng/mL) and 30% during frozen storage (2805829 ng/mL) by day 5. In contrast, at pH 7–9 demonstrated improved short-term stability, but gradual degradation was evident during prolonged storage. At pH 7, day-5 recoveries were approximately 55% during refrigerated storage (28051530 ng/mL) and 40% during frozen storage (28051131 ng/mL). Similar trends were observed at pH 8 and 9. Direct comparison within identical pH conditions showed that frozen storage partially attenuated degradation under strongly acidic conditions but did not prevent substantial long-term loss. Overall, urine pH exerted a stronger influence on myoglobin stability than storage temperature. Conclusions Urinary myoglobin exhibits significant pre-analytical instability when assessed relative to baseline concentrations over storage periods of up to five days. Urine pH is the dominant determinant of stability, while storage temperature provides only partial and inconsistent protection. Even under neutral to alkaline conditions, gradual degradation occurs during prolonged storage. These findings emphasize the importance of immediate urine pH adjustment and standardized pre-analytical handling to ensure reliable urinary myoglobin measurement in routine clinical laboratory practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of early qualitative myoglobinuria with in-hospital mortality and time to hospital discharge in burn patients: A 5-year retrospective cohort study.Burns : journal of the International Society for Burn Injuries · 2026
- Inter-unit variability and rapid depletion of 2,3-diphosphoglycerate in stored red blood cells: implications for transfusion practice in neurocritical carebioRxiv · 2026
- Effects of storage temperature and delayed analysis on routine biochemical and haematological test resultsScientific Reports · 2026
- Marked Inter-Unit Variability and Early Depletion of 2,3-Diphosphoglycerate During Red Blood Cell Storage.Cells · 2026
- B-346 Storage Stability of HbA1c in Whole Blood: Method-Dependent Interference on Ion-Exchange HPLC and Degradation Kinetics Characterized by LC–MSClinical Chemistry · 2026
- Bioelectrical impedance-derived total body water for predicting exertional rhabdomyolysis-induced acute kidney injury during military training: a prospective cohort study.BMC nephrology · 2026