A-111 Head-to-head comparison of two clinical molecular microbiology tests to detect bacteria in positive blood cultures
Ashley Strother, Daniel Rhoads
Key points
From the paper's conclusion- Both tests can rapidly identify and characterize bacteria grown in blood culture.
Abstract
Background Using rapid molecular tests to identify and characterize bacteria in positive blood cultures can help to rapidly optimize antimicrobial therapy. The LIAISON PLEX® Gram-Positive and Gram-Negative Blood Culture Assays (Diasorin) recently received FDA-clearance in 2025, and the BioFire® Blood Culture Identification 2 panel (BCID2; bioMérieux) received FDA-clearance in 2020. Methods This study compared the performance of LIAISON PLEX® & BioFire® BCID2. Testing was performed in a single laboratory in 2025 & 2026. The results were compared to standard-of-care (SOC) agar subculture as the reference method. Fresh or frozen samples obtained from BacT/ALERT® Virtuo® (bioMérieux) SOC testing were tested. Samples were included if gram-positive cocci or gram-negative bacilli were observed in the SOC Gram stain, and samples were excluded if multiple microbial morphologies were recognized during the SOC Gram stain. Only one sample per subject was included. Samples in which LIAISON PLEX® or BioFire® BCID2 results were discordant with SOC results were further investigated and described. Results A total of 151 positive blood culture bottles (100 gram-negative, 51 gram-positive) were tested, and 13 discordant results are described in the Table. In total, 2.0% (3/151) had bacterial isolates detected by SOC that were not designed to be detected by LIAISON PLEX® (Bacteroides fragilis, Moraxella osloensis, & Veillonella species), and 1.3% (2/151) had bacterial isolates not designed to be detected by BioFire® BCID2 (M. osloensis & Veillonella species). Although samples with mixed Gram stain findings were excluded, 8 of the 151 samples proved to be polymicrobial by SOC upon subculture, and four of these polymicrobial samples yielded discordant results. Of the 143 monomicrobial samples, nine had discrepant results. LIAISON PLEX® failed to detect targets (false-negative results) in six cases, and five were the failure to detect a coagulase-negative staphylococci. BioFire® BCID2 detected targets that were not identified by SOC (false-positive results) in six cases, and it did not detect one target (false-negative) in one case. Of the seven discordant BioFire® BCID2 results, four involved coagulase-negative staphylococci. When considering the performance of each sample, LIAISON PLEX® had 95.9% (142/148) positive percent agreement (PPA) and 100% (142/142) positive predictive value (PPV). BioFire® BCID2 had 99.3% (148/149) PPA and 96.0% (143/149) PPV. Conclusion LIAISON PLEX® demonstrated high specificity, but decreased sensitivity compared to SOC, and BioFire® BCID2 demonstrated high sensitivity but decreased specificity compared to SOC. The sensitivity and specificity strengths and weaknesses of these two assays are likely attributable to the different molecular methods employed by the systems in which LIAISON PLEX® uses a direct probe method, and BioFire® BCID2 uses an amplification method. Samples that were polymicrobial by SOC and samples that were falsely identified as polymicrobial by molecular testing were commonly discordant with SOC. Coagulase-negative staphylococci were a common source of discordant results. Both tests can rapidly identify and characterize bacteria grown in blood culture. Disclosure. Financial support for this study was provided by Diasorin.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-101 Comparison of BioFire and Verigene Blood Culture Tests for Identification of Polymicrobial Gram-Positive/Gram-Negative CulturesClinical Chemistry · 2026
- Preliminary Single-Center Evaluation of the Alifax Molecular Mouse Sepsis Panel for Rapid Detection of Bloodstream Pathogens.Diagnostics (Basel, Switzerland) · 2026
- Fast Microbiology: A Pilot Study Comparing Culture-Independent Digital PCR and Blood Culture for Pathogen Detection in Sepsis.International journal of molecular sciences · 2026
- Concerns about “Evaluation of alternative blood culture systems in detecting pathogenic bacteria: a multi-site, observational prospective study” by Hu et al., 2026The Lancet Regional Health - Western Pacific · 2026
- An institutional investigation of false-positive signals in an automated blood culture system: evaluating clinical predictors and molecular etiologies.Microbiology spectrum · 2026
- Analytical and Clinical Evaluation of a Fully Automated Direct-from-Whole-Blood Multiplex PCR Assay Using Large-Volume Reverse Elution for Rapid Bloodstream Infection Diagnosis.Antibiotics (Basel, Switzerland) · 2026