Clinical Chemistry

A-081 Validation of the Liason Plex Respiratory Flex Assay using Alternative Lower Respiratory Tract Specimen Types

Teresa Kirkpatrick, Danielle Ingebrigtsen, Jeffrey Whitman, Rama Yakubu

Key points

From the paper's conclusion
  • These data support the use of the assay for lower respiratory testing for respiratory pathogen detection in high-acuity clinical settings.

Abstract

Background The LIAISON PLEX Respiratory Flex Assay (Diasorin) is an FDA-cleared, fully automated sample-to-answer RT-PCR multiplex panel approved for nasopharyngeal swabs (NPS). Because lower respiratory tract (LRT) specimens are frequently submitted for evaluation of viral pneumonia in hospitalized and immunocompromised patients, we validated assay performance in LRT matrices, with emphasis on bronchial alveolar lavage (BAL), bronchial wash (lower), and endotracheal aspirate (lower), to support clinical implementation beyond the approved specimen type. Methods Accuracy was assessed using previously characterized and contrived respiratory specimens, including upper and LRT sources. LRT samples included BAL (lower), and endotracheal aspirates (lower); nasal wash specimens were also evaluated as additional fluid matrices. For fluid sources, two pre-analytic workflows were compared: (1) sonication followed by centrifugation at 2700 rpm for 5 minutes and (2) sonication followed by centrifugation at 2000g for 10 minutes, using supernatant for testing. Sputolysin pre-treatment was validated for mucoid LRT fluids to ensure pipettability. Discrepant results were resolved by repeat testing on the LIAISON PLEX platform and/or confirmatory testing on comparator platforms used in routine practice (e.g., Verigene, ePlex, NxTAG RPP). Analytical sensitivity in LRT matrices was verified at expected manufacturer limits of detection (LoD) for representative targets (including influenza A H1, influenza B, RSV A, parainfluenza 1 and 4, SARS-CoV-2, human metapneumovirus, rhinovirus/enterovirus, adenovirus, and Mycoplasma pneumoniae) with duplicate testing across LRT specimen types and processing workflows with an acceptance criterion of 2/2 detected. LoD studies were conducted by spiking in nucleic acid controls (Zeptometrix or ATCC) for all targets in all LRT specimen matrices at the concentrations reported in the package insert. Results A total of 51 lower respiratory tract (LRT) true-positive (TP) results and 17 LRT true-negative (TN) results were included in the cumulative performance analysis. For LRT specimens, false positives (FP) = 0 and false negatives (FN) = 0 following discrepancy resolution (specificity 100%, sensitivity 100%, total agreement 100%). Target-specific LRT performance demonstrated TP counts (n) for influenza A (5), including influenza A H1 (2) and influenza A H3 (3), influenza B (2), RSV A/B (4), human metapneumovirus (4), rhinovirus/enterovirus (4), adenovirus (7), parainfluenza virus 1 (6), parainfluenza virus 2 (2), parainfluenza virus 3 (5), parainfluenza virus 4 (5), SARS-CoV-2 (2), and Mycoplasma pneumoniae (5). LRT TN counts included influenza A (12), adenovirus (2), parainfluenza virus 3 (4), and Mycoplasma pneumoniae (5); other targets did not have LRT TN specimens available in the evaluated study set. LRT limit-of-detection verification met acceptance criteria (2/2 detected) for all evaluated targets at the designated concentrations, and sputolysin pre-treatment enabled reliable processing of viscous LRT samples without compromising expected detection. Conclusion The LIAISON PLEX Respiratory Flex Assay demonstrated acceptable clinical performance in lower respiratory specimens (BAL, bronchial wash, and endotracheal aspirate) when paired with standardized pre-analytic processing (sonication plus centrifugation) and sputolysin pre-treatment for mucoid samples. These data support the use of the assay for lower respiratory testing for respiratory pathogen detection in high-acuity clinical settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers