Biomedicines

Development and Validation of a Novel Oral Orotracheal Bronchoalveolar Lavage Device for Improved Bronchoalveolar Lavage in Mice.

Mujie Zhang, Jiacheng Deng, Wenxin Ji, Xiaoyan Tian, Leyao Liang, Yingjun Li, Zhenyu Liao, Liang Peng,

KingMed School of Laboratory Medicine, Guangzhou Medical University, Guangzhou 511436, China. · Key Laboratory of Biological Targeting Diagnosis, Therapy and Rehabilitation of Guangdong Higher Education Institutes, The Fifth Affiliated Hospital, Guangzhou Medical University, Guangzhou 510700, China.

Preclinical

Key points

From the paper's conclusion
  • We developed a novel oral orotracheal bronchoalveolar lavage device (OOBL) and evaluated its procedural performance, bronchoalveolar lavage fluid (BALF) quality, and recovery of inflammatory readouts.

Abstract

Background: Bronchoalveolar lavage (BAL) is widely used to assess pulmonary inflammation, but conventional tracheotomy-based lavage (TBL) requires tracheal incision, cannulation, and fixation and may contribute to procedural trauma and blood contamination. We developed a novel oral orotracheal bronchoalveolar lavage device (OOBL) and evaluated its procedural performance, bronchoalveolar lavage fluid (BALF) quality, and recovery of inflammatory readouts. Methods: Thirty-two female C57BL/6J mice (n = 8 per group) received oropharyngeal instillation of PBS or lipopolysaccharide (LPS; 5 mg/kg) and underwent BAL 12 h later using TBL or OOBL. Operating time, procedural success, and BALF recovery were assessed together with BALF cell counts, protein, flow cytometry, and ELISA; lung histology and qRT-PCR were used to validate the inflammatory model. Results: OOBL shortened operating time (3.9 ± 0.7 vs. 8.7 ± 1.2 min) and increased BALF recovery (88.5 ± 4.0% vs. 64.4 ± 18.8%). Under PBS conditions, OOBL yielded lower BALF red blood cell counts and protein concentrations than TBL. Under LPS-induced inflammatory conditions, OOBL yielded higher BALF MPO, IL-1β, and TNF-α, with a trend towards higher total and white blood cell counts, whereas IL-6 did not differ between lavage methods. Conclusions: OOBL eliminates tracheal incision, catheter insertion through the tracheal incision, and suture fixation, although a limited cervical incision and tracheal exposure are still required for visual confirmation of placement. These preliminary findings suggest that OOBL may be an efficient and reproducible BAL device for murine pulmonary research, although further validation is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers