A-034 Post-COVID near-threshold instability with PST™ vs. Barricor™: implications for redundant testing and resource use.
Jenna Rimkus, Albert Tsui, Allison Venner, George Cembrowski
Key points
From the paper's conclusion- Conclusion In the post-COVID period, near-threshold hs-cTnT instability was more likely to translate into redundant confirmatory testing in PST™-using systems than in Barricor™-using systems.
Abstract
Background Barricor™ plasma blood collection tubes produce cleaner plasma with less residual cellular content compared with traditional plasma separator tubes (PST™). Although Barricor™ tubes have slightly higher acquisition costs, reduced preanalytical variability may influence near-threshold (14 ng/L) instability in high-sensitivity cardiac troponin T (hs-cTnT) testing. We evaluated post-COVID hs-cTnT variability and associated downstream resource utilization in two Alberta metropolitan centres using PST™ (Calgary) and Barricor™ (Edmonton). Methods Troponin “Episodes” were defined as =3 consecutive hs-cTnT tests performed within 6 hours. Boundary crossings were defined as transitions across the 14 ng/L clinical decision threshold (=14 vs <14). Analytical noise was modelled using site-specific, concentration-banded SDs (<10, 10 to <15, 15 to <20, 20 to<30 ng/L), assigned stepwise based on the starting value of each comparison. Noise-consistent changes were defined as = 3.29 SD (99.9% threshold). A “Bounce-back” event required a threshold crossing followed by immediate reversion on the subsequent test, with both changes meeting the noise criterion. These events were interpreted as potentially redundant confirmatory testing. Episode-level Bounce-back rates were compared between sites, and redundant testing was translated into estimated ED bed-hours and downstream costs using observed inter-test delays. Results A total of 2,299 Calgary PST™ Episodes and 4,950 Edmonton Barricor™ Episodes were analyzed. Boundary crossings occurred more frequently with PST™ than Barricor™ (7.30% vs 2.57%; odds ratio 2.99, p<0.01). Among episodes with crossings, PST™ episodes were more likely to demonstrate noise-consistent Bounce-back events (9.1% vs 2.5%; Odds Ratio 3.92, p=0.013), corresponding to approximately 8 redundant confirmatory tests per 1,000 qualifying episodes in Calgary versus fewer than 1 per 1,000 in Edmonton. Mean inter-test delay was similar between sites (3.3-3.5 hours). Redundant testing in Calgary was associated with an estimated 25-26 additional ED bed-hours per 1,000 patients compared with fewer than 4 bed-hours in Edmonton, translating into incremental per-1,000-patient costs of approximately $2,400-$5,000 under plausible cost assumptions. Conclusion In the post-COVID period, near-threshold hs-cTnT instability was more likely to translate into redundant confirmatory testing in PST™-using systems than in Barricor™-using systems. Differences in concentration-stratified analytical performance may contribute to downstream testing and ED resource utilization. These findings suggest that preanalytical tube selection may influence system-level costs despite differences in acquisition price.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-033 Multisite, chronological (2015-2024) determinations of total hs-cTnT variation (analytical, biological, and preanalytical) demonstrate post-COVID increases in total intrapatient cTnT variation that degrade the optimal interpretation of low serial hs-cTnTClinical Chemistry · 2026
- A-002 Evaluation of the Abbott i-STAT devices for both high-sensitivity cardiac troponin I and creatinineClinical Chemistry · 2026
- Real-world impact of implementing a 0/2-hour point-of-care high-sensitivity troponin pathway: interrupted time series and winter-matched difference-in-differences analysisEuropean Heart Journal · 2026
- Real-world analytical and diagnostic evaluation of the Abbott i-STAT Alinity point-of-care high-sensitivity troponin I assay in a UK emergency department.Annals of clinical biochemistry · 2026
- The effectiveness of point of care high sensitivity troponin testing to improve Emergency Department flow: a multi-centre controlled interrupted time seriesmedRxiv · 2026
- Impact of point-of-care high-sensitivity troponin testing on index admission and 30-day costs: secondary analysis of a randomised controlled trialEuropean Heart Journal · 2026