Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.
Sebastian Mussnig, Luis Naar, Marieta Theodorakopoulou, Janosch Niknam Saeidi, Joachim Beige, David Keane, Daniel Schneditz, Pantelis Sarafidis,
Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria. · Kuratorium for Dialysis and Transplantation e.V. (KfH), Neu-Isenburg, Germany.
Key points
From the paper's conclusion- We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP/PWC trends. We further establish that physiological BP/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.
Abstract
BACKGROUND: Ambulatory blood pressure (BP) and pulse wave characteristics (PWCs) are stronger predictors of mortality than conventional pre-/post-dialytic BP in hemodialysis. While BP is recommended to be managed primarily by reducing fluid overload (FO), associations of FO with interdialytic BP/PWCs remain unknown. METHODS: Bioimpedance-derived FO and interdialytic 44-h BP/PWCs were analyzed at baseline and follow-up of a quality improvement project involving targeted fluid management. Trended cosinor linear mixed-effects models assessed intra-patient associations of post-dialysis FO with interdialytic BP/PWCs. RESULTS: We analyzed 120 visits (77/43 at baseline/follow-up) from 80 patients (70% male; mean age 68 ± 14 years; median dialysis vintage 38 [18-64] months). Post-dialysis FO decreased in baseline hypervolemic patients from 2.7 ± 1.3 L to 0.9 ± 1.7 L. Every 1 L increase in post-dialysis FO at the patient level was associated with increased peripheral BP (systolic: 4.54 mmHg, P < 0.001; diastolic: 2.55 mmHg, P < 0.001), peripheral resistance (0.03 s*mmHg/mL, P = 0.011), augmentation index (1.38%, P = 0.007), wave amplitudes (forward: 0.56 mmHg, P = 0.025; backward: 0.61 mmHg, P = 0.027), reservoir pressure peak (3.83 mmHg, P < 0.001), and pulse wave velocity (0.12 m/s, P = 0.007). Higher FO was associated with decreased interdialytic slopes of all BPs, peripheral resistance, backward wave amplitude, reservoir peak pressure, and pulse wave velocity. FO interacted with circadian rhythms of stroke volume, peripheral resistance, forward wave amplitude, and excess pressure peak. CONCLUSIONS: We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP/PWC trends. We further establish that physiological BP/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Target weight optimization based on a modified VExUS protocol in hemodialysis: the VexHD prospective multi-center study.Cardiorenal medicine · 2026
- Association of 24 h Pulse Pressure Derived from Ambulatory Blood Pressure Monitoring with All-Cause and Cardiovascular Mortality in Patients Undergoing Peritoneal Dialysis: A Prospective Cohort Study.Journal of clinical medicine · 2026
- The Effects of Fluid Management Approaches on Renin-Angiotensin-Aldosterone System Activity and Blood Pressure Control in Patients on Dialysis.Seminars in dialysis · 2026
- Unsupervised Clustering of Intradialytic Blood Pressure Patterns and Their Associations With Body Composition in Patients Undergoing Chronic Hemodialysis.Electrolyte & blood pressure : E & BP · 2026
- Ultrasound-guided haemodynamic profiling in haemodialysis patients: a single-centre prospective observational study protocol.Frontiers in nephrology · 2026
- Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis.Kidney360 · 2026