The Effects of Fluid Management Approaches on Renin-Angiotensin-Aldosterone System Activity and Blood Pressure Control in Patients on Dialysis.
Feng Mingming, Yu Yan, Yang Ting
Department of Liver Surgery, West China Hospital/West China School of Nursing, Sichuan University, Chengdu, Sichuan, China. · Haemodialysis Center, Department of Nephrology, West China Hospital/West China School of Nursing, Sichuan University, Chengdu, Sichuan, China.
Key points
From the paper's conclusion- Absolute blood volume monitoring was associated with greater short-term suppression of endocrine activation and better hemodynamic outcomes than clinical assessment or bioimpedance-guided monitoring during the 12-week follow-up period.
Abstract
BACKGROUND: Chronic fluid imbalance in maintenance hemodialysis can increase cardiovascular risk through activation of the renin-angiotensin-aldosterone pathway. This study compared the endocrine and hemodynamic effects of three fluid management strategies in adults receiving maintenance hemodialysis in a prospective two-center observational cohort study. METHODS: Six hundred patients were assigned to fluid management by clinical assessment, bioimpedance-guided monitoring, or absolute blood volume monitoring, with 200 patients in each group. Plasma renin activity, angiotensin II, aldosterone, systolic and diastolic blood pressure, and arterial stiffness were measured at baseline and Weeks 6 and 12. Between-group and over-time differences were analyzed using adjusted longitudinal and covariance-based models. Additional analyses examined variation by age, fluid status pattern, and sodium self-management. RESULTS: By Week 12, plasma renin activity, angiotensin II, and aldosterone increased in the clinical assessment group showed smaller increases or minimal change in the bioimpedance-guided group and declined in the absolute blood volume monitoring group. The absolute blood volume monitoring group also showed the greatest improvement in blood pressure and arterial stiffness over follow-up. In addition, this group had the lowest frequency of intradialytic hypotension and the strongest improvement in patient self-management measures. CONCLUSIONS: Absolute blood volume monitoring was associated with greater short-term suppression of endocrine activation and better hemodynamic outcomes than clinical assessment or bioimpedance-guided monitoring during the 12-week follow-up period.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lower Hospitalization Rates During Fluid Management with Relative Blood Volume Monitoring: A Retrospective Cohort Analysis.Journal of clinical medicine · 2026
- Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.Clinical kidney journal · 2026
- Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis.Kidney360 · 2026
- Toward Precision Fluid Management in Hemodialysis: Adaptive Ultrafiltration Guided by Continuous Relative Blood Volume Monitoring.Journal of clinical medicine · 2026
- Blood pressure in haemodialysis: measurement, volume control and drug selection.Journal of nephrology · 2026
- Manual Versus Automated Biofeedback-Guided Strategies for Isonatremic Hemodialysis: A Real-World Comparative Study.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2026