Association of 24 h Pulse Pressure Derived from Ambulatory Blood Pressure Monitoring with All-Cause and Cardiovascular Mortality in Patients Undergoing Peritoneal Dialysis: A Prospective Cohort Study.
Jing Yu, Rui Yang, Xi Xia, Jianwen Yu, Yagui Qiu, Jianbo Li, Xiao Yang, Haiping Mao,
Department of Nephrology, the First Affiliated Hospital, Sun Yat-Sen University, 58th, Zhongshan Road II, Guangzhou 510080, China.
Key points
From the paper's conclusion- Whether 24 h PP (24 h PP) derived from ambulatory BP monitoring (ABPM) is independently associated with all-cause and cardiovascular (CV) mortality in peritoneal dialysis (PD) patients remains unclear.
Abstract
Background/Objectives: Pulse pressure (PP), an indirect hemodynamic marker reflecting the pulsatile component of blood pressure, has been linked to adverse outcomes in dialysis patients. Whether 24 h PP (24 h PP) derived from ambulatory BP monitoring (ABPM) is independently associated with all-cause and cardiovascular (CV) mortality in peritoneal dialysis (PD) patients remains unclear. Methods: This sub-cohort, nested within a single-center prospective PD database, enrolled 165 patients with baseline 24 h ABPM. The 24 h PP was analyzed continuously and in tertiles. All-cause mortality was assessed by Cox regression and CV mortality by Fine-Gray competing-risk modeling. The median follow-up was 47.4 months, counted from the date of ABPM completion. Results: During follow-up, 48 patients (29.1%) died, including 28 CV deaths (58.3% of all deaths). Per 1-SD increment in 24 h PP, the adjusted hazard ratio (HR) for all-cause mortality was 1.39 (95% confidence interval [CI] 1.03-1.87; p = 0.032), and the adjusted subdistribution hazard ratio (SHR) for CV mortality was 1.44 (95% CI 1.06-1.94; p = 0.018). The highest tertile showed elevated risks of all-cause (HR 3.47; 95% CI 1.12-10.70; p = 0.031) and CV mortality (SHR 5.11; 95% CI 1.32-19.79; p = 0.018) versus the lowest, persisting after adjustment for office PP. Conclusions: Elevated ABPM-derived 24 h PP is independently associated with increased all-cause and CV mortality in PD patients after adjustment for office PP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nighttime Systolic Blood Pressure and Cardiovascular and All-Cause Mortality in Peritoneal Dialysis Patients: A Single-Center Prospective Cohort Study.Journal of clinical medicine · 2026
- SBP-hyper-burden: a novel predictor of cardiovascular mortality in patients undergoing maintenance hemodialysisEuropean Heart Journal · 2026
- Associated factors of elastic and stiffening components of pulse pressure based on 45 517 database of 24 h ambulatory blood pressure monitoring.Journal of human hypertension · 2026
- Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.Clinical kidney journal · 2026
- U-shaped association of time-averaged cumulative diastolic blood pressure slope with mortality in hemodialysis patients.Kidney & blood pressure research · 2026
- Prognostic Value of Ambulatory Blood Pressure Monitoring in Patients Admitted With Acute Decompensated Heart Failure: A Prospective Observational Study From a Tertiary Referral Centre.International journal of heart failure · 2026