A transparent gel pad bolus enabling direct skin recognition in surface-guided radiation therapy.
Shunta Hirano, Kenji Matsumoto, Masakazu Otsuka, Naoto Miyazaki, Takuya Uehara, Hajime Monzen
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, 1-14-1, Miharadai, Minami-ku, Sakai-shi, Osaka, 590-0197, Japan. · Department of Central Radiology, Kindai University Hospital, 1-14-1, Miharadai, Minami-ku, Sakai-shi, Osaka, 590-0197, Japan.
Key points
From the paper's conclusion- Conclusions The transparent gel pad bolus enabled direct SGRT-based recognition of the underlying skin surface while maintaining clinically relevant bolus functionality.
Abstract
OBJECTIVES: To evaluate the feasibility of repurposing a transparent ultrasound gel pad as a radiotherapy bolus, we focused on dosimetric performance and compatibility with surface-guided radiation therapy (SGRT). METHODS: A gel pad bolus composed of tamarind seed gum and polyhydric alcohols was compared with a conventional gel bolus and a thermoplastic bolus. Percent depth dose was measured for 6 MV and 10 MV photon beams and 6 MeV and 9 MeV electron beams. Straight-line optical transmittance was assessed over 380-830 nm. Surface recognition accuracy was quantified using the AlignRT SGRT system on a breast phantom. RESULTS: The gel pad produced a measurable bolus effect for both photon and electron beams, although superficial dose enhancement was lower than that of conventional materials (85.5% vs 90.3-91.5% at 6 MV). Deep doses beyond dmax agreed within 1% for photon beams. At 730 nm, the gel pad bolus demonstrated high transmittance (92.3%), compared with the gel (19.8%) and HM (36.6%) boluses. The SGRT recognition rate with the gel pad bolus (89.10%) was comparable to the no-bolus condition (92.93%, p = 0.13), whereas conventional boluses significantly reduced recognition (p < 0.001). CONCLUSIONS: The transparent gel pad bolus enabled direct SGRT-based recognition of the underlying skin surface while maintaining clinically relevant bolus functionality. ADVANCES IN KNOWLEDGE: Optical transparency enables SGRT monitoring through a bolus, highlighting optical compatibility as an important design consideration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a customized three-dimensional bolus using transparent gel wax and its application in electron beam therapy.Physical and engineering sciences in medicine · 2026
- A patch-based bolus technique for total scalp irradiation: dosimetric impact of conformity and reproducibility.Journal of radiation research · 2026
- Assessment of beam-control time delay in surface-guided radiotherapy gating using ExacTrac dynamic: impact of surface color and tracking area shape.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Maskless head and neck radiotherapy using surface-guided radiation therapy: initial clinical feasibility of real-time setup, intrafraction monitoring, and automatic beam-hold.Journal of applied clinical medical physics · 2026
- Optimizing Computed Tomography-derived Surface Monitoring for Accurate Cancer Radiotherapy Setup.In vivo (Athens, Greece) · 2026
- ExacTrac Dynamic Surface-Guided Setup Versus Tattoo-Based Positioning in Breast Cancer Radiotherapy: A Retrospective Comparison of Setup Accuracy and Preparation Time.Cancers · 2026