Establishment of a method for detecting BRAF V600E mutation using an epitaxial probe: Fluorescence quantitative PCR with the classical four-primer Amplification Refractory Mutation System-PCR architecture.
Binbin Dong, Wenjing Du, Qianwen Li, Yuming Gong, Chaoran Xia, Yongchen Yang
Department of Pediatrics, Huashan Hospital, Affiliated to Fudan University, Shanghai, 201100, China. · Department of Integrative Medicine, Huashan Hospital, Fudan University, Shanghai, 201100, China.
Key points
From the paper's conclusion- This study presents an innovative Epitaxial Probe-Allelic Specific PCR (EPAS‑PCR) for highly sensitive and specific fluorescence detection of the BRAF V600E mutation.
Abstract
This study presents an innovative Epitaxial Probe-Allelic Specific -Polymerase Chain Reaction (EPAS‑PCR) for highly sensitive and specific fluorescence detection of the BRAF V600E mutation. By attaching a target‑unrelated extension sequence to the 5' end of the inner allele‑specific primer and pairing it with a universal primer and a TaqMan probe, the method converts the classical four‑primer Amplification Refractory Mutation System PCR (ARMS‑PCR) into a closed‑tube real‑time quantitative PCR (qPCR) system, eliminating gel electrophoresis. The core innovation decouples and cascades mutation recognition with signal generation: only when the inner primer specifically extends the mutant template does the downstream probe system produce fluorescence. The outer primer F1 contributes pre‑amplification and competitively suppresses wild‑type non‑specific amplification. Using Taq polymerase lacking 3'→5' exonuclease activity is critical for specificity. The assay exhibits good linearity (R 2 ≥ 0.99) from 1 × 104 to 1 × 108 copies/μL. In plasmid mixtures, it detects 0.137% mutant fraction at 106 copies/reaction and 0.412% at 104 copies/reaction; in genomic DNA standards, the limit of detection is 0.2%, superior to conventional ARMS‑PCR. Compared with ARMS‑PCR, EPAS‑PCR avoids the sensitivity loss and non‑specificity risks arising from omitting outer primers and introducing extra mismatches. Direct comparison shows that ARMS‑PCR without F1 produces false positives around cycle 40, whereas complete EPAS‑PCR remains signal‑free up to 50 cycles. The EPAS‑PCR method offers advantages such as modular design, straightforward development, and reliable performance. In addition to detecting the BRAF V600E mutation, it is also applicable to the detection of other nucleic acid point mutations, representing a novel strategy with broad application prospects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Blocker Primer-Assisted LAMP Coupled with Pyrococcus furiosus Argonaute Enables Specific and Sensitive Detection of EGFR Mutations in NSCLC.Analytical chemistry · 2026
- Integration of PNA-mediated PCR and CRISPR/Cas13a for highly sensitive detection of EGFR T790M mutation in circulating tumor DNA.Molecular and cellular probes · 2026
- Exonuclease III-Proofread high-fidelity primer exchange reaction enables ultrasensitive analysis of prostate cancer MicroRNA.Biosensors & bioelectronics · 2026
- A Two-Step Strategy Based on Fpg Recognition and RCA-CRISPR/Cas12a for Ultrasensitive Detection of Gene Mutation.Analytical chemistry · 2026
- HPMES: an ultra-sensitive mutation enrichment strategy for FLT3-ITD MRD monitoring in acute myeloid leukemia.Biosensors & bioelectronics · 2026
- Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants.Analytical chemistry · 2026