Biosensors & bioelectronics

HPMES: an ultra-sensitive mutation enrichment strategy for FLT3-ITD MRD monitoring in acute myeloid leukemia.

Manlu Yang, Wei Wu, Huili Bai, Jie Zhao, Yijie Gong, Li Wang, Tianzi Wang, Shiyi Feng,

Key Laboratory of Clinical Laboratory Diagnostics (Chinese Ministry of Education), College of Laboratory Medicine, Chongqing Medical Laboratory Microfluidics and SPRi Engineering Research Center, Chongqing Medical University, Chongqing, 400016, PR China. · The Center for Clinical Molecular Medical Detection, Engineering Research Center of Chongqing Education Commission of China for IVD Technology Innovation and Translation, Laboratory Medicine Center, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, PR China.

Key points

From the paper's conclusion
  • Here, we report a hairpin primer-mediated mutation enrichment strategy (HPMES) coupled with mediator probe-PCR technology for sensitive FLT3-ITD detection.

Abstract

FMS-like tyrosine kinase 3 internal tandem duplications (FLT3-ITD) are among the most common oncogenic drivers in acute myeloid leukemia (AML) and are strongly associated with adverse clinical outcomes. Current clinical guidelines recommend measurable residual disease assays with a sensitivity down to 0. 01% variant allele frequency, yet existing approaches are constrained by either the limited sensitivity of conventional PCR methods or the complexity and cost of NGS. Here, we report a hairpin primer-mediated mutation enrichment strategy (HPMES) coupled with mediator probe-PCR technology for sensitive FLT3-ITD detection. By incorporating a rationally engineered stem-loop architecture that sequesters the primer 3' terminus, HPMES enables highly selective recognition and amplification of mutant alleles through toehold-mediated strand displacement. Systematic optimization identified an optimal stem length of 7-10 bp, while strategically introduced mismatches further improved discrimination of AT-rich ITD junction variants. Compared with conventional linear primers, HPMES markedly suppressed wild-type background amplification and achieved reliable detection of FLT3-ITD mutations at frequencies as low as 0.001%, demonstrating a limit of detection of ≤1.1 copies/μL. Moreover, multiplex HPMES-qPCR assays enabled simultaneous detection of multiple ITD subclones and showed complete concordance with NGS in clinical sample validation. Collectively, HPMES-qPCR provides a rapid, cost-effective, and ultrasensitive platform for FLT3-ITD MRD monitoring, offering a preliminary alternative solution for precision risk stratification and individualized therapeutic management in AML.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers