Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants.
Zhijin Li, Min Qing, Jianbo Wang, Chao Yu
Chongqing Key Laboratory for Pharmaceutical Metabolism Research, College of Pharmacy, Chongqing Medical University, Chongqing400016, P. R. China.
Key points
From the paper's conclusion- Overall, this PTU-One-Pot strategy provides a rapid and sensitive isothermal platform for low-abundance mutation enrichment and analysis.
Abstract
Sensitive detection of low-abundance single-nucleotide variants (SNVs) remains challenging because rare mutant alleles are frequently masked by overwhelming wild-type DNA backgrounds. Herein, we develop a photo-programmable temporally uncoupled one-pot isothermal sensing platform (PTU-One-Pot) for sensitive enrichment and detection of the EGFR L858R mutation. The platform integrates restriction endonuclease-mediated wild-type DNA digestion with recombinase polymerase amplification (RPA) in a closed tube. To resolve the intrinsic kinetic conflict between relatively slow wild-type DNA digestion and rapid RPA amplification, RPA primers are modified with a photocleavable 6-nitropiperonyloxymethyl (NPOM) group. During the initial phase, NPOM-caged primers suppress RPA amplification, allowing MlsI restriction endonuclease to selectively digest wild-type templates. Subsequent brief ultraviolet irradiation removes the NPOM protection and activates RPA amplification of remaining mutant-type templates. Mechanistic studies confirm RPA photo-programmable trigger and sequence-selective wild-type template cleavage. Droplet digital PCR, high-resolution melting, Sanger sequencing verify that PTU-One-Pot can effectively eliminate wild-type templates and convert the final products from wild-type-dominated to mutant-enriched. Under optimized conditions, fluorescence readout achieves a limit of detection of 0.05% variant allele frequency, showing high specificity to EGFR L858R mutation. Lateral flow assay integration enables low-instrument visual detection at 1% variant allele frequency. Evaluation using 23 formalin-fixed paraffin-embedded patient samples demonstrates that both fluorescence and lateral flow readouts are consistent with next-generation sequencing and droplet digital PCR reference results. Overall, this PTU-One-Pot strategy provides a rapid and sensitive isothermal platform for low-abundance mutation enrichment and analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Two-Step Strategy Based on Fpg Recognition and RCA-CRISPR/Cas12a for Ultrasensitive Detection of Gene Mutation.Analytical chemistry · 2026
- A Self-Locking DNAzyme Platform for Highly Specific Sensing of Low-Abundance Single-Base Mutations.Analytical chemistry · 2026
- Allele-Specific CRISPR-Cas9-Based Ratiometric Fluorescence Platform for Portable EGFR L858R Mutation DetectionAnalytical Chemistry · 2025
- Blocker Primer-Assisted LAMP Coupled with Pyrococcus furiosus Argonaute Enables Specific and Sensitive Detection of EGFR Mutations in NSCLC.Analytical chemistry · 2026
- Programmable Argonaute-mediated single-nucleotide variant sequencing of cell-free DNA for multi-cancer early detectionNature Communications · 2025
- Multiplexed Nucleic Acid Detection Using Sequence-Specific Cleavage Mediated by Repair Endonucleases.ACS sensors · 2026