Analytical chemistry

Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants.

Zhijin Li, Min Qing, Jianbo Wang, Chao Yu

Chongqing Key Laboratory for Pharmaceutical Metabolism Research, College of Pharmacy, Chongqing Medical University, Chongqing400016, P. R. China.

Key points

From the paper's conclusion
  • Overall, this PTU-One-Pot strategy provides a rapid and sensitive isothermal platform for low-abundance mutation enrichment and analysis.

Abstract

Sensitive detection of low-abundance single-nucleotide variants (SNVs) remains challenging because rare mutant alleles are frequently masked by overwhelming wild-type DNA backgrounds. Herein, we develop a photo-programmable temporally uncoupled one-pot isothermal sensing platform (PTU-One-Pot) for sensitive enrichment and detection of the EGFR L858R mutation. The platform integrates restriction endonuclease-mediated wild-type DNA digestion with recombinase polymerase amplification (RPA) in a closed tube. To resolve the intrinsic kinetic conflict between relatively slow wild-type DNA digestion and rapid RPA amplification, RPA primers are modified with a photocleavable 6-nitropiperonyloxymethyl (NPOM) group. During the initial phase, NPOM-caged primers suppress RPA amplification, allowing MlsI restriction endonuclease to selectively digest wild-type templates. Subsequent brief ultraviolet irradiation removes the NPOM protection and activates RPA amplification of remaining mutant-type templates. Mechanistic studies confirm RPA photo-programmable trigger and sequence-selective wild-type template cleavage. Droplet digital PCR, high-resolution melting, Sanger sequencing verify that PTU-One-Pot can effectively eliminate wild-type templates and convert the final products from wild-type-dominated to mutant-enriched. Under optimized conditions, fluorescence readout achieves a limit of detection of 0.05% variant allele frequency, showing high specificity to EGFR L858R mutation. Lateral flow assay integration enables low-instrument visual detection at 1% variant allele frequency. Evaluation using 23 formalin-fixed paraffin-embedded patient samples demonstrates that both fluorescence and lateral flow readouts are consistent with next-generation sequencing and droplet digital PCR reference results. Overall, this PTU-One-Pot strategy provides a rapid and sensitive isothermal platform for low-abundance mutation enrichment and analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants — Science Skim