49 Assay Performance and Test Utilization: A Comparison of E-Z Cup Point-of-care Device and Alinity c Automated Urine Drug Screening Platforms
Cheryl Mathis, Jason Goodfellow, Vrajesh Pandya
Key points
From the paper's conclusion- Overall, the transition to the automated Alinity immunoassay enhanced test utilization, analytical reliability, and operational efficiency.
Abstract
Background Urine drug screening (UDS) by immunoassay is a critical component of evaluating drug exposure and overdose in acute care settings, while LC‑MS/MS–based confirmatory testing plays an essential role in pain management and behavioral health settings. At our large academic medical center, we previously employed a 12‑analyte UDS panel using the E‑Z Split Key® Cup II, a manual immunochromatographic point-of-care device. To reduce interpretive ambiguity associated with visual multi-analyte cup readings and to mitigate errors from manual result entry, we transitioned in November 2025 to an automated 10‑analyte homogeneous immunoassay on the Abbott Alinity™ c platform. Depending on clinical need, providers were offered options to order either screen‑only testing or a screen with reflex to confirmation. Objectives Because these two methods differ substantially in assay principle and workflow, this study aimed to compare post‑implementation performance and test utilization patterns of the Alinity platform relative to the E‑Z Cup using retrospective data analysis. Methods UDS and corresponding LC‑MS/MS confirmatory results from May 2024 to May 2025 were analyzed, representing a 6-month period before and after the transition. Test utilization, reflex ordering frequency, screen positivity rates, and false positive rates were evaluated using R (v4.5.1). Results The total number of UDS panels performed on the Alinity platform was 5,159 (3,404 unique patients), compared with 5,437 panels using the E‑Z Cup (3,979 unique patients). In both periods, most tests originated from the emergency department and behavioral health settings. The proportion of tests ordered with reflex to confirmation increased substantially following implementation of Alinity (24.1%; N = 1,245) compared with E‑Z Cup (8.5%; N = 342), reflecting streamlined ordering pathways. Screen positivity rates also differed significantly by method. The Alinity platform demonstrated an overall screen positivity rate of 43.8% (545 panels positive for ≥1 drug), whereas the E‑Z Cup yielded 24.6% (84 panels positive for ≥1 drug). For both systems, cannabinoids, stimulant amines, and benzodiazepines were the most frequently detected analytes. Stimulant amines also demonstrated the highest false positive rate for both methods, although substantially lower on Alinity (51.3%) as compared to E‑Z Cup (95.0%). Using paired LC‑MS/MS results, the true positivity rate across analytes was 85.5% for Alinity versus 56.3% for E‑Z Cup. Mean turnaround time (TAT) modestly improved on Alinity (21.2 ± 1.0 minutes) relative to the E‑Z Cup (22.3 ± 1.5 minutes). Conclusion The creation of a more streamlined UDS panel on the Alinity platform led to more consistent turnaround time, increased adoption of reflex testing, higher true positive screening performance, and reduced false positive rates for amphetamines. Overall, the transition to the automated Alinity immunoassay enhanced test utilization, analytical reliability, and operational efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-379 Comparative Performance Evaluation of Two Multi-Drug Urine Screening Cups with Fentanyl DetectionClinical Chemistry · 2026
- Comparison of Immunoassay Results near Cutoff Values with LC-MS/MS in Individuals with Substance Use Disorder Under Probation.Metabolites · 2026
- Nonadherence, Diversion, or Analytical Limitation? A Negative Urine Opiate Screen in a Patient Prescribed HydrocodoneLabMed · 2026
- Use of direct injection UHPLC-MS/MS for antibiotic population use assessment by wastewater analysis - application to laboratory and monitoring studies.Analytical methods : advancing methods and applications · 2026
- 34 Development and Implementation of a Broad-spectrum Urine Drug Panel in a Clinical Toxicology LaboratoryAmerican Journal of Clinical Pathology · 2026
- Fully automated robotic sample preparation coupled with UPLC-MS/MS for high-throughput screening of 19 nitazene analogues in human urine.Journal of pharmaceutical and biomedical analysis · 2026