Hybrid thermoelectric and air cooling of a 104-cell lithium-ion battery pack coupled with thermal modelling of cooling performance, power cost and safe operating limits
Sivakrishnamraju R, Rajay Vedaraj I S
Key points
From the paper's conclusion- This study develops a coupled electro-thermal model of a 104-cell (13S8P) cylindrical pack in a staggered duct in which cell, air, cold-plate and hot-side temperatures are solved simultaneously from energy balances and fan power is derived from the tube-bank friction factor.
Abstract
Thermoelectric coolers (TECs) are proposed to augment forced-air battery thermal management, and hybrids are commonly reported to exceed the combined performance of their constituent modes. Such assessments prescribe the thermoelectric hot-side temperature rather than solving for it, leaving the reported interaction unverified. This study develops a coupled electro-thermal model of a 104-cell (13S8P) cylindrical pack in a staggered duct in which cell, air, cold-plate and hot-side temperatures are solved simultaneously from energy balances and fan power is derived from the tube-bank friction factor. Heat generation follows the Bernardi formulation, convection the Zukauskas correlation, and module properties come from catalogue data. The model reproduces a closed-form analytical solution to 1×10¹² K, with a grid convergence index of 0.06%. Additivity was assessed on a temperature basis⁻ (S=0.607±0.102, 48 conditions), where the hybrid achieves substantially less than the sum of the individual depressions, and on a capacity basis (SQ=0.994±0.079, 72 conditions), where it is additive within scatter. Prescribing the hot side at Tamb+10 K standalone against Tamb+3 K hybrid raises SQ to 1.096, identifying it as the source of the reported enhancement. Deactivating the thermoelectric stage while retaining the cold plate recovers 25–60% of the uniformity improvement for under 9% of the parasitic power. At equal electrical power, augmentation is advantageous in 45% of conditions. With airflow limited to 1.2 m s¹, fan-only regulation exceeds 45 °C for 1033 s of a 2400 s profile at 30 °C⁻ ambient whereas the hybrid remains below the limit, and across 2000 Monte Carlo builds at 60 A the limit is exceeded in 99.8% of forced-air against 1.2% of hybrid cases. Fixed-current operation overcools the pack at low load, and the cold plate falls below the dew point across 22% of hybrid operating points. A fan-first control hierarchy with a dew-point-limited thermoelectric stage is recommended.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid response of the thermoelectric active battery thermal management system assisted with phase change materialsJournal of Advanced Research · 2026
- Thermoelectric-based battery thermal management with cooling and energy recoveryThe Innovation Energy · 2026
- Comprehensive numerical investigation of ambient temperature and discharge rate effects on thermal performance of a 104-cell Li-ion battery pack with zig-zag arrangement and hybrid TEC–forced convection coolingFrontiers in Mechanical Engineering · 2026
- Investigation of the Effects of Design and Operating Parameters on the Thermal Management System Performance of a Lithium-Ion Battery Pack for Sustainable Energy StorageSustainability · 2026
- Shared-Source Air–Liquid Hybrid Thermal Management and Pareto-Optimized Supervisory Control for Peak-Shaving Battery Energy Storage SystemsEnergy & Fuels · 2026
- Hybrid cooling approach using PCM and liquid cold plate for battery thermal management of cylindrical cellsInternational Journal of Numerical Methods for Heat & Fluid Flow · 2025