Comprehensive numerical investigation of ambient temperature and discharge rate effects on thermal performance of a 104-cell Li-ion battery pack with zig-zag arrangement and hybrid TEC–forced convection cooling
Siva Krishnam Raju Rallabandi, I. S. Rajay Vedaraj
Key points
From the paper's conclusion- This study investigates a 104-cell (13S8P) NCR18650BD lithium-ion battery pack in a Zig-zag (staggered) arrangement using a Python/SciPy lumped-parameter thermal model that combines Joule heat, SOC-dependent reversible entropic heat, temperature-dependent internal resistance, radiation, forced convection, and thermoelectric-cooler (TEC) physics.
Abstract
Effective battery thermal management must remain reliable under changing ambient temperature, discharge demand, and airflow availability. This study investigates a 104-cell (13S8P) NCR18650BD lithium-ion battery pack in a Zig-zag (staggered) arrangement using a Python/SciPy lumped-parameter thermal model that combines Joule heat, SOC-dependent reversible entropic heat, temperature-dependent internal resistance, radiation, forced convection, and thermoelectric-cooler (TEC) physics. A full factorial design was evaluated over 108 operating conditions (four ambient temperatures, nine discharge currents, and three airflow velocities), with five seeded Monte Carlo repetitions per condition, yielding 540 simulated measurements. The SOC-dependent entropic coefficient was propagated through the solver by SOC-window averaging for steady-state cases and by Coulomb-counted SOC updates for transient discharge. The rerun showed that the 45 °C natural-convection safe-current limit decreases from 40.3 A at 20 °C to 22.5 A at 35 °C. With ambient-dependent TEC hot-side derating, the corresponding natural-convection TEC-assisted extended limits decrease from 70.8 A to 57.0 A, demonstrating that TEC expands the operating envelope but does not eliminate ambient-temperature sensitivity. At v = 7 m/s, all tested currents up to 60 A remain safe except the 35 °C case, where the no-TEC threshold is 52.4 A. Two-way ANOVA at v = 7 m/s identified ambient temperature as the dominant factor ( η 2 = 0.6348), followed by discharge current ( η 2 = 0.3585), with a small interaction contribution ( η 2 = 0.0016). A physics-enhanced Ridge model achieved R 2 = 0.9858 and RMSE = 0.630 °C on a condition-level holdout split, while a closed-form no-TEC BMS equation achieved R 2 = 0.9279 and RMSE = 1.419 °C. The revised results provide corrected isotherm coordinates, an updated safe-current table, clearer operating-envelope figures, and an explicit TEC activation map for battery-management implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hybrid thermoelectric and air cooling of a 104-cell lithium-ion battery pack coupled with thermal modelling of cooling performance, power cost and safe operating limitsEngineering Research Express · 2026
- A multi-physics, fully liquid-cooled battery pack model development for winter-summer driving using a holistic reverse-engineering methodeTransportation · 2025
- Analysis of Active and Passive Thermal Management System for Cooling of Lithium‐Ion Battery PackEnergy Technology · 2025
- Electro-Thermal Modeling and Long-Term Degradation-Exposure Analysis of Active BTMS Under Tropical Heat-Soak ConditionsWorld Electric Vehicle Journal · 2026
- Heat Generation Characteristics of Lithium‐Ion Batteries for Grid‐Forming Energy Storage Under High Temperature Differences and High Discharge RatesInternational Journal of Energy Research · 2026
- Rapid response of the thermoelectric active battery thermal management system assisted with phase change materialsJournal of Advanced Research · 2026