A New Optimal Scheduling Algorithm in an Islanded Hybrid Microgrid System considering Load Priorities
K Rambabu, Ramudu Ganji, D Surekha, D Arun Kumar, FURQUAN NADEEM
Key points
From the paper's conclusion- To demonstrate the effectiveness of the proposed scheduling algorithm, the problem is also solved without incorporating load priorities, and the results show that critical loads like hospitals (H-1, H-2 & H-3) receive only 65.15%, 66.4% & 64.1% of their required energy and other high priority loads like industries (I-1, I-2) receive only 75.6% and 74.41% of their required energy which indicates th
Abstract
This article presents an optimal scheduling algorithm for an islanded hybrid microgrid system, considering load priorities to enhance overall network performance while ensuring an uninterrupted power supply to critical loads. The network includes multiple distributed generation (DG) sources such as a Diesel Engine Generator (DE), Micro turbine (MT), Solar Photovoltaic (PV) system, Wind Turbine (WT), and Energy Storage System (ESS), along with various types of loads. Loads are prioritized by categorizing them in to priority levels based on their critical operational requirements during islanded conditions, and within the priority level, analytic hierarchy process (AHP) is used to assign weights to the loads based on multiple attributes. Three objective functions are considered to formulate the scheduling problem as a non-linear programming (NLP) problem, evaluated under four distinct operating scenarios. Each scenario focuses on minimizing one objective function while adhering to network constraints and security limits. Notably, in Case 4, goal programming approach is followed to model the scheduling problem under limited generation conditions to assure continuous power supply to high-priority loads. To demonstrate the effectiveness of the proposed scheduling algorithm, the problem is also solved without incorporating load priorities, and the results show that critical loads like hospitals (H-1, H-2 & H-3) receive only 65.15%, 66.4% & 64.1% of their required energy and other high priority loads like industries (I-1, I-2) receive only 75.6% and 74.41% of their required energy which indicates that the scheduling is done randomly without meeting the requirements of loads. In contrast, the proposed scheduling framework ensures 100% continuous power supply to critical loads and approximately 96% of the required energy to industries demonstrating the superiority of proposed work.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive Energy Management and Control of an Autonomous PV-Wind-Diesel-BESS Hybrid Microgrid: A Case Study on Tioman Island, MalaysiaResults in Engineering · 2025
- Multi-agent systems based on hierarchical voltage control in active low- and medium-voltage electrical distribution networksElectric Power Systems Research · 2025
- Hybrid Microgrid Power Management via a CNN–LSTM Centralized Controller Tuned with Imperialist Competitive AlgorithmMathematics · 2025
- Energy Symbiosis in Isolated Multi-Source Complementary Microgrids: Diesel–Photovoltaic–Energy Storage Coordinated Optimization Scheduling and System Resilience AnalysisEnergies · 2025
- Energy Management Optimization for an Island Microgrid with Renewable Energy, Storage, and Demand ResponseEnergies · 2026
- Hierarchical RL–ANFIS Energy Management with Supervisory Override for Priority-Aware Microgrids Under Measured Iraqi Grid OutagesEnergies · 2026