A patient-specific Winston-Lutz system for multi-target, single isocentre radiotherapy.
Kassia M M Schenkels, R Lee MacDonald, Patricia A K Oliver
Physics and Atmospheric Science, Dalhousie University, 1453 Lord Dalhousie Dr, Halifax, Nova Scotia, B3H 4R2, Canada. · Medical Physics, Nova Scotia Health Authority, 5788 University Avenue, Halifax, Nova Scotia, B3L 2C2, Canada.
Key points
From the paper's conclusion- Objective: To develop a quality assurance (QA) system for verifying patient-specific radiation targeting accuracy of radiotherapy linear accelerators (linacs) for multi-target, single isocentre stereotactic radiosurgery (SRS).
Abstract
OBJECTIVE: To develop a quality assurance (QA) system for verifying patient-specific radiation targeting accuracy of radiotherapy linear accelerators (linacs) for multi-target, single isocentre stereotactic radiosurgery (SRS). APPROACH: The QA system consists of a phantom containing a 3D array of possible radiopaque target (BB) positions and associated software. Software determines the in-phantom BB positions most closely corresponding to the patient's lesion locations. A dynamic conformal arc (DCA) plan was generated using the couch/collimator/gantry angles corresponding to the patient's treatment plan. During plan delivery, images are acquired at 25 frames per second using the linac's electronic portal imaging device (EPID). BB positions relative to the field centroid were detected using a Hough circle detection algorithm. The radiation field was detected using image thresholding. MAIN RESULTS: Validation with synthetic data showed BB position discrepancies of 0.23 mm (mean) and 0.53 mm (maximum), respectively, which do not exceed the synthetic phantom resolution, meaning that the test can be considered successful. Field area discrepancies were 2.60% (mean) and 3.33% (maximum) of the expected field size. Intentional translation and rotations were applied, demonstrating the sensitivity and accuracy of the system. A combined analysis of BB positions and field area discrepancies are necessary to fully assess linac targeting accuracy. As a further validation step, results for a single BB case were found to agree with the analysis results from independent software within 0.19 mm. For a 6 BB test case, maximum and mean 2D differences in expected and detected BB positions were 2.21 mm and 1.03 mm respectively. Field area discrepancies were 2.17 cm2 (mean) and 4.20 cm2 (maximum) or 3.75% and 7.98% of the expected field size. SIGNIFICANCE: This QA system defines plan-specific machine isocentricity for single-isocentre multi-target SRS according to a chosen tolerance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- End to end dosimetric and geometric verification of single isocenter multitarget stereotactic radiosurgery using an anthropomorphic phantom: external audit validation.Radiological physics and technology · 2026
- Impact of daily machine performance check on prediction models for patient‐specific quality assurance of multiple‐target stereotactic radiosurgeryMedical Physics · 2026
- Characterization of high-resolution detector response for stereotactic patient-specific QA across different TPS-linac systems.Radiation and environmental biophysics · 2026
- Optimizing TrueBeam jaw calibrations to reduce positional errors at customizable gantry and collimator anglesJournal of Applied Clinical Medical Physics · 2026
- It’s not your device, it’s how you use it – Sensitivity and specificity of PSQA devices in the SEAFARER head and neck studyRadiotherapy and Oncology · 2026
- Assessing Gamma Index Sensitivity to Selected Linear Accelerator Mechanical Errors Using Various Dosimetric Systems.Journal of clinical medicine · 2026