Impact of daily machine performance check on prediction models for patient‐specific quality assurance of multiple‐target stereotactic radiosurgery
Nicola Lambri, Giacomo Reggiori, Leonardo Nicotera, Veronica Vernier, Carmela Galdieri, Ciro Franzese, Daniele Loiacono, Stefano Tomatis,
Key points
From the paper's conclusion- Background Single‐isocenter multiple‐target (SIMT) stereotactic radiosurgery (SRS) delivered with standard linear accelerators (linacs) achieves high dose conformity through modulated fields with small multi‐leaf collimator (MLC) apertures, making patient‐specific quality assurance (PSQA) a critical component of radiotherapy programs.
Abstract
Background Single‐isocenter multiple‐target (SIMT) stereotactic radiosurgery (SRS) delivered with standard linear accelerators (linacs) achieves high dose conformity through modulated fields with small multi‐leaf collimator (MLC) apertures, making patient‐specific quality assurance (PSQA) a critical component of radiotherapy programs. Complexity metrics are established predictors of PSQA results, while daily quality control checks of linacs represent an additional potential source of predictive information. Purpose To investigate whether integrating machine performance check (MPC) parameters with complexity metrics improves machine learning model prediction of the gamma passing rate (GPR) in SIMT SRS PSQA. Methods A total of 1054 volumetric modulated arcs from 245 consecutive patients treated with SIMT SRS were included. The median total planning target volume was 5.03 cc (range 0.31–119.65 cc) treated with 10MV‐FFF beams in 1 fraction of 20 or 24 Gy, or in 3–5 fractions of 27–32 Gy. PSQA was performed field‐by‐field using an electronic portal imaging device (EPID) with a gamma criterion of 3%/1 mm and a 95% tolerance limit. Eighteen arc‐specific plan complexity metrics (aPCM) and ten MPC features were considered. Feature selection based on hierarchical clustering of the Spearman's rank correlation matrix yielded fourteen features (five aPCM, nine MPC). Data were split chronologically according to the QA session date, with the earliest 80% of arcs used for training and the most recent 20% for testing. Four histogram gradient boosting models were trained to predict the GPR of each arc: model A (aPCM and MPC), model B (aPCM only), model C (MPC only), and model D (MPC predicting the residuals of model B). Model performance was evaluated using mean absolute error (MAE) and area under the receiver operating characteristic curve (AUC), with bootstrap 95% confidence intervals. Differences between models A and B were assessed with Cohen's f 2 and a Wilcoxon signed‐rank test on residuals. Model explainability was obtained with SHAP (SHapley Additive exPlanations). Results Model A showed the best performance (MAE = 1.7% [1.5, 1.9]; AUC = 0.87 [0.79, 0.93]), closely followed by model B (MAE = 1.8% [1.6, 2.0]; AUC = 0.83 [0.75, 0.89]) and model D (MAE = 1.8% [1.6, 2.0]; AUC = 0.83 [0.76, 0.90]). Model C performed markedly worse, particularly in classification ability (MAE = 2.0% [1.7, 2.2]; AUC = 0.64 [0.58, 0.71]). The incremental effect of adding MPC features was small‐to‐medium but not significant on residuals ( f 2 = 0.13 [0.02, 0.27]; Wilcoxon p = 0.213). SHAP identified aPCM as the primary predictors in models A and B, with median MLC gap showing the highest contribution (average absolute SHAP value = 1.66%). Among MPC features, couch rotation accuracy showed the highest contribution ( = 0.27%), considerably smaller than that of aPCM (group mean = 0.07% vs. 0.48%). Conclusions MPC features did not provide meaningful complementary information for predicting PSQA results of SIMT SRS. Complexity metrics related to MLC aperture characteristics were the dominant predictors, indicating an association between arc complexity and PSQA outcomes in SIMT SRS. To reduce variability in EPID field‐by‐field PSQA results, we recommend controlling the complexity of SIMT SRS arcs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Linac performance benchmarking: Feasibility of a web-based tool for comparison of local machine performance check (MPC) results with the global community.Journal of applied clinical medical physics · 2026
- General versus site specific quantile random forest models for virtual patient-specific quality assurance of VMAT plans.Journal of applied clinical medical physics · 2026
- Machine learning-based prediction of gamma passing rates in VMAT prostate external radiation therapy plans.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Characterization of high-resolution detector response for stereotactic patient-specific QA across different TPS-linac systems.Radiation and environmental biophysics · 2026
- Predicting VMAT patient-specific quality assurance outcome using a machine learning workflow.Physical and engineering sciences in medicine · 2026
- End to end dosimetric and geometric verification of single isocenter multitarget stereotactic radiosurgery using an anthropomorphic phantom: external audit validation.Radiological physics and technology · 2026