Interference-Driven Loss of Spectral Specificity in Long-Wavelength NIR Lactate Sensing in Complex Media.
Shree Krishnamoorthy, Walter Messina, Andrea Visentin, Fergus Mccarthy, Ray Burke, Stefan Andersson-Engels
Biophotonics@Tyndall, Tyndall National Institute, Tyndall National Institute, Mardyke, Cork, Ireland, Cork, Co. Cork, T12R5CP, Ireland. · School of Computer Science & IT, University College Cork, University College Cork, Cork, Co. Cork, T12 K8AF, Ireland.
Key points
From the paper's conclusion- Existing monitoring approaches are intermittent and invasive.
Long-wavelength near-infrared (LWNIR) spectroscopy enables the possibility of non-invasive, real-time lactate sensing, but its translation has been hindered by calibration instability and reduced spectral specificity in complex biological media.
Abstract
Continuous lactate monitoring is valuable for managing peritoneal dialysis in patients with chronic kidney disease (CKD), where lactate acts both as a marker of dialysis efficacy and an early indicator of sepsis. Existing monitoring approaches are intermittent and invasive. Long-wavelength near-infrared (LWNIR) spectroscopy enables the possibility of non-invasive, real-time lactate sensing, but its translation has been hindered by calibration instability and reduced spectral specificity in complex biological media. These limitations arise from overlapping biomolecular absorption signatures and the strong, dispersive nature of water absorption in this region. This study investigates how biochemical and mechanical interference affects LWNIR-based lactate estimation. To do this rigorously, we developed clinically informed biophantoms incorporating glucose, albumin and urea as key interferents relevant to CKD and peritoneal dialysis. These biophantoms were first examined in buffered media and then extended to human serum to capture additional biological complexity. To emulate conditions similar to dialysis operation, serum was also circulated through a cuvette under controlled flow. Standard machine-learning regressors successfully recovered lactate concentrations; however, spectral specificity deteriorated substantially in more complex matrices, as reflected by the increased broadening of wavelength-selection profiles derived from variable importance in projection (VIP) analysis. The newly developed clinically relevant biophantoms improved wavelength localisation relative to conventional buffer-only systems. These findings underscore the need for realistic, clinically informed calibration strategies to achieve spectrally robust LWNIR-based lactate sensing, and they outline a pathway towards reliable optical monitoring technologies for dialysis and wider CKD management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wearable Sweat Biosystem with Dual Diffusion-Limiting Interface for Dynamic Hyperlactatemia Management in Critical Care.ACS nano · 2026
- Clinical Evaluation of Microneedle Biosensors for Continuous Lactate Monitoring in Critically Ill PatientsACS Sensors · 2026
- Lactate and lactylation in sepsis-associated acute kidney injury: clinical evidence from the MIMIC-IV database and mechanistic insightsFrontiers in Medicine · 2025
- Reply to the comment by Kuzukıran Kocataş on "Can full-stay lactate burden predict ICU mortality? The importance of a defined prediction time".Journal of intensive care · 2026
- Non-invasive continuous interstitial fluid lactate monitoring via alternating-polarity reverse iontophoresis.Biosensors & bioelectronics · 2026
- Prognostic performance of an 8-zone lung ultrasound B-line score combined with 24-hour lactate clearance for 28-day all-cause mortality in adults with sepsis: a single-center retrospective cohort studyThe Egyptian Journal of Bronchology · 2026