Clinical Evaluation of Microneedle Biosensors for Continuous Lactate Monitoring in Critically Ill Patients
Omeed Djassemi, An-Yi Chang, W. Cameron McGuire, Emily Mitchell, Tamoghna Saha, Ticiana Fernandes, J. Yang, Michael Miller,
University of California San Diego
Key points
From the paper's conclusion- We present a clinical evaluation of a minimally invasive microneedle-based electrochemical biosensor for real-time interstitial fluid (ISF) lactate monitoring.
Abstract
Continuous lactate monitoring is critical for early detection and management of sepsis, shock, and metabolic stress, yet current serum assays remain invasive, intermittent, and resource-intensive. We present a clinical evaluation of a minimally invasive microneedle-based electrochemical biosensor for real-time interstitial fluid (ISF) lactate monitoring. The microneedle biosensor features a platinum working electrode modified with a lactate oxidase reagent layer and a polyvinyl chloride anti-fouling membrane for H 2 O 2 -mediated amperometry, toward highly selective and stable ISF lactate detection. In a pilot study of twenty-one participants across an intensive care unit, emergency department, cardiopulmonary exercise testing, and controlled laboratory settings, two enzyme-based microneedle sensors placed on the forearm and thigh continuously tracked lactate for 4 h. Sensor performance demonstrated strong agreement with blood lactate assays ( r = 0.94), high diagnostic accuracy for hyperlactatemia (>4 mmol/L; receiver operating characteristic analysis, area under the curve = 0.95), and minimal bias (−0.028 mmol/L) over a wide dynamic range (0.7−22.9 mmol/L) with high selectivity against interferents. No significant ISF−blood differences ( p > 0.05) or adverse events were observed. These findings establish microneedle biosensors as a promising platform for precision medicine, with considerable potential to transform sepsis care, guide resuscitation, and improve assessment of exertional dyspnea.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fenestrated Microneedle Biosensor for Continuous In Vivo Lactate Monitoring in Interstitial Fluid.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Dissolvable sacrificial interfacial shielding for stable microneedle arrays-based electrochemical dynamic monitoring of sepsis-associated lactate.Biosensors & bioelectronics · 2026
- Wearable Sweat Biosystem with Dual Diffusion-Limiting Interface for Dynamic Hyperlactatemia Management in Critical Care.ACS nano · 2026
- Recent advances in microneedle-based electrochemical biosensors for monitoring biomarkers in interstitial fluidThe Analyst · 2026
- Smartphone-assisted upconversion nanoparticles-aptamer-based probe functionalized hydrogel microneedles for rapid interstitial fluid lactate profiling.Talanta · 2026
- Non-invasive continuous interstitial fluid lactate monitoring via alternating-polarity reverse iontophoresis.Biosensors & bioelectronics · 2026