Thirty Minute Ahead Risk Modeling of CGM Derived Personalized Glycemic Excursions from Food Log, Contextual, and Wearable Features: A Participant Level Evaluation.
Türker Berk Dönmez, Mohammed Mansour
Sakarya University, University Street Serdivan, Serdivan, Sakarya, 54050, Turkey. · Department of Mechatronics Engineering, Sakarya University of Applied Sciences, University Street, Serdivan, 54050, Turkey.
Key points
From the paper's conclusion- We performed a retrospective feasibility analysis of the public PhysioNet BIG IDEAs Lab dataset: 16 participants with Dexcom G6 CGM, Empatica E4 streams, food logs, and demographic variables.
Abstract
Continuous glucose monitoring (CGM) characterizes glycemic variability, but whether food log, contextual, and wrist sensor information can indicate a future participant relative excursion remains uncertain. We performed a retrospective feasibility analysis of the public PhysioNet BIG IDEAs Lab dataset: 16 participants with Dexcom G6 CGM, Empatica E4 streams, food logs, and demographic variables. PersLow, PersNorm, and PersHigh outcomes were defined from each participant's prior 24 hour CGM distribution; CGM was excluded from model predictors. Targets were matched at the exact clock time 30 minutes after prediction, and evaluation used leave-one-participant out folds with participant level uncertainty. The revised 87 variable full multimodal LightGBM model achieved mean participant macro F1 0.462 (95% bootstrap CI 0.424-0.499; median 0.488, IQR 0.410-0.518). A 39 variable food/context comparator achieved 0.443 (95% CI 0.409-0.476); the paired full-minus-comparator difference was +0.020 (95% CI 0.009-0.033). Removing explicit sensor missingness variables left predictions unchanged, and removing broader coverage proxies produced macro F1 0.465. A separate retrospective random-forest calibration analysis using personal CGM labels yielded common window macro F1 of 0.380 at 0 hours and 0.431 at 72 hours; this does not establish prospective personalization effectiveness. Most PersLow and PersHigh targets did not cross clinical glucose thresholds, and corrected event analyses retained nontrivial false alarm rates. The confidence intervals quantify participant variation conditional on the fitted analyses and do not account for the extensive model development and selection process. The small observed internal difference does not establish a clinically meaningful or externally generalizable wearable benefit. These exploratory findings do not establish glucose measurement, diagnosis, CGM free initialization, or prospective alerting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated mealtime identification from continuous glucose monitoring to assess long-term postprandial glycemic exposure in non-diabetic adultsScientific Reports · 2026
- GlucoAgent: Personalized Glucose Forecasting from Multimodal Personal ContextarXiv · 2026
- Subtyping and Prediction of the Glucose Based on the Hybrid Modeling of Deep Learning and Dietary Stimulated Glucose Metabolism Dynamical Model.Bulletin of mathematical biology · 2026
- Forecasting glucose from CGM and sparse meal logs with a residual-gated multimodal transformermedRxiv · 2026
- Short-term postprandial glucose monitoring reveals stable traits from noisy free-living mealsmedRxiv · 2026
- Quantifying the Contributions of Food, Glucose, Sleep, and Microbiome Data to Personalized Glycemic Response Prediction.Current developments in nutrition · 2026