Automated mealtime identification from continuous glucose monitoring to assess long-term postprandial glycemic exposure in non-diabetic adults
Juen Guo, Vipul Periwal, Aaron Hengist, Stephanie T. Chung, Arthur S. Sherman, Valerie L. Darcey
Key points
From the paper's conclusion- We developed and evaluated a bidirectional long short-term memory model with conditional random field decoding (BiLSTM-CRF) to identify meal onsets directly from CGM traces and estimate 2 h postprandial glucose exposure.
Abstract
Continuous glucose monitoring (CGM) can quantify long-term glycemic exposure, but postprandial interpretation requires reliable temporal anchors for meal onset. We developed and evaluated a bidirectional long short-term memory model with conditional random field decoding (BiLSTM-CRF) to identify meal onsets directly from CGM traces and estimate 2 h postprandial glucose exposure. CGM datasets from 66 adults without diabetes who participated in three inpatient metabolic studies were used; meal onset times were recorded by research nurses. The model was trained using Abbott CGM data and evaluated in independent Abbott and Dexcom datasets. During development, the model achieved an accuracy of 0.93, precision of 0.89, recall of 0.84, and F1 score of 0.87 at a 15 min tolerance. In the independent Abbott dataset, precision, recall, and F1 score (mean ± SD) were 0.87 ± 0.11, 0.83 ± 0.11, and 0.85 ± 0.11 at a 15 min tolerance, and 0.95 ± 0.06, 0.91 ± 0.08, and 0.93 ± 0.07 at a 30 min tolerance. Model-predicted and recorded postprandial AUCs were highly correlated, and predicted AUCs showed similar associations with glycemic variability metrics. Automated meal-event identification may reduce reliance on manual food logging and enable scalable assessment of postprandial glycemic exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thirty Minute Ahead Risk Modeling of CGM Derived Personalized Glycemic Excursions from Food Log, Contextual, and Wearable Features: A Participant Level Evaluation.Medical engineering & physics · 2026
- Short-term postprandial glucose monitoring reveals stable traits from noisy free-living mealsmedRxiv · 2026
- Forecasting glucose from CGM and sparse meal logs with a residual-gated multimodal transformermedRxiv · 2026
- Continuous Glucose Monitoring Reveals Glycemic Patterns Associated with End-Organ Alterations in Early DysglycemiamedRxiv · 2026
- Modeling strategies for CGM data: A scoping review of mechanistic, machine learning, and hybrid approaches in diabetes managementComputers in Biology and Medicine · 2026
- Joint Estimation of the Meal Response and the Between-Meal Process in Continuous Glucose Monitoring with Annotated Meal Times.Metabolites · 2026