Journal of Physics: Conference Series

Advancements in Smart Wearable 3D printed Insoles for Ground Reaction Force Estimation and Gait Analysis

Neeharika Singh, Nishant Kumar Singh, Mimoh Kumar Patel, Nitin Sahai

Review

Key points

From the paper's conclusion
  • Smart insoles built on force-sensitive resistors, piezoelectric ceramics, capacitive arrays, or 3D-printed conductive thermoplastic elastomer (cTPE) foam address this gap, with commercial systems such as Moticon Insole3, FeetMe, and XSENSOR reporting intraclass correlation coefficients (ICCs) of 0.88–0.94 for vertical GRF and spatiotemporal gait parameters during steady walking.

Abstract

Continuous, ambulatory measurement of ground reaction force (GRF) is needed to extend gait analysis beyond the laboratory and into real-world settings, particularly for conditions such as functional flatfoot, which affects 10–25% of the population worldwide. Floor-mounted force plates and optical motion capture remain the laboratory gold standard, but their cost, rigid setup, and short capture windows make them unsuitable for long-term, free-living monitoring. Smart insoles built on force-sensitive resistors, piezoelectric ceramics, capacitive arrays, or 3D-printed conductive thermoplastic elastomer (cTPE) foam address this gap, with commercial systems such as Moticon Insole3, FeetMe, and XSENSOR reporting intraclass correlation coefficients (ICCs) of 0.88–0.94 for vertical GRF and spatiotemporal gait parameters during steady walking. This review synthesizes design, fabrication, calibration, and validation evidence from thirteen primary studies and, in doing so, identifies a pattern not previously articulated in this literature: reported accuracy tracks the sophistication of the computational model used to compensate for sensor imperfections more closely than it tracks the underlying sensor physics itself. Cross-study comparison further shows that three limitations persist irrespective of sensor type: an inability to resolve shear from normal forces, drift from viscoelastic relaxation in piezoresistive materials over multi-day use, and degraded accuracy under high-impact or multi-axial loading. Closing these gaps, we argue, depends less on further sensor-material substitution than on three coordinated advances: three-dimensional transducer geometries capable of separating force components, drift-robust feature representations, and machine learning pipelines validated for clinical translation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Advancements in Smart Wearable 3D printed Insoles for Ground Reaction Force Estimation and Gait Analysis — Science Skim