Temporal Consistency and Averaging Sensitivity of Released Smart-Insole Gait Summaries in Participants with and without Knee Osteoarthritis.
Mi-Ae Yang, Kang-Su Ha
Department of Science and Technology Convergence, Graduate School, Chosun University, Gwangju 61452, Republic of Korea. · Department of Psychiatry, Rainbow Hospital, Gwangju 61924, Republic of Korea.
Key points
From the paper's conclusion- These results characterize release-specific temporal consistency and qualify model-based averaging projections; they do not validate calendar-duration prescriptions, clinical change thresholds, or the underlying device.
Abstract
Repeated smart-insole outputs may support longitudinal gait research, but consistency of processed summaries does not establish device accuracy or a clinical monitoring schedule. We analyzed 10 released observations per participant from AI Hub dataset 71966, retaining 178 participants (89 provider-labeled normal and 89 knee osteoarthritis) after exclusion of a previously reported opposing-label duplicate pair. Analyses combined absolute-agreement intraclass correlations (ICCs), participant-bootstrap intervals, residual variability, nonoverlapping 2-, 3-, and 5-observation averages, and exploratory adjusted coefficient-of-variation (CV) models. Single-observation ICCs were 0.827-0.844 for midfoot/rearfoot pressure, 0.663-0.727 for stride length, speed, and forefoot pressure, 0.398 for distance, and approximately 0.014 for balance. Five-observation empirical ICCs were lower than Spearman-Brown predictions for every non-balance endpoint; gait speed yielded 0.887 versus 0.927 and left stride length 0.870 versus 0.908. Left-balance residual SD was 2.388 in the released scale despite low median CV. Linear-programming median regression and solution-choice sensitivity replaced warning-prone bootstrap fitting; the maximum change of a nominal interval endpoint from its reference was 0.0996 CV percentage points. Calendar dates, wear time, and criterion measurements were unavailable. These results characterize release-specific temporal consistency and qualify model-based averaging projections; they do not validate calendar-duration prescriptions, clinical change thresholds, or the underlying device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment.Medical engineering & physics · 2026
- Leakage-Resistant Evaluation of Gait Mat and Multisensor Biomechanical Features for Knee Osteoarthritis Screening: A Subject-Level Data Integrity Study.Bioengineering (Basel, Switzerland) · 2026
- Adaptive Gait Biofeedback With Participant-Held-Out Modeling and Participant-Specific Updating in Chronic Ankle InstabilityarXiv · 2026
- How many repeated observations are enough for digital gait summaries? A multi-dataset framework for sampling sufficiency in older adults.Journal of neuroengineering and rehabilitation · 2026
- Individual step and participant mean validation of Gaitly's smartphone video-based gait analysis system.Frontiers in rehabilitation sciences · 2026
- Sensor Fusion Pipeline for Gait Analysis Using Insole-Embedded Inertial Measurement Units (IMUs).Sensors (Basel, Switzerland) · 2026