DuDoTransGAN: Dual-Domain transformer based generative adversarial unsupervised network for metal artifact reduction in paired and unpaired CT.
Yan Wang, Jia Deng, Zhaojie Peng, Yule Zeng, Jikang Jiang, Langtao Zhou, Zisan Zeng, Hong Zhou
The First Affiliated Hospital, Department of Radiology, Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China. · The Hengyang Medical School, University of South China, Hengyang, Hunan, 421001, China.
Key points
From the paper's conclusion- DuDoTransGAN is an adaptable unsupervised dual-domain MAR framework that performs effectively on paired synthetic and unpaired clinical data, producing high-quality, clinically interpretable CT images in the presence of metallic implants.
Abstract
PURPOSE: Metal artifacts from implants degrade CT image quality, while supervised metal artifact reduction (MAR) methods require paired clean data that are rarely available clinically. METHODS: In this retrospective study, we developed DuDoTransGAN, an unsupervised dual-domain generative adversarial network for paired and unpaired training. It was evaluated on a publicly available paired synthetic dataset (SYN; 90,000 training and 2,000 test slices) and a clinical unpaired knee CT dataset (KNE; 19,032 slices from 66 patients; mean age, 55.8 ± 16.1 years; 36 males), including 6,168 slices with metal artifacts. On KNE, two radiologists independently assessed five image-quality aspects using Likert scales, with ratings reviewed by a senior radiologist. RESULTS: In the paired SYN experiment, DuDoTransGAN achieved a mean PSNR of 38.19 dB, the highest mean SSIM (0.975), and the lowest mean RMSE (5.65) among unsupervised methods. Performance remained stable with increasing metal-mask size, demonstrating robustness under larger-metal-mask conditions. In the unpaired KNE experiment, inter-rater agreement was excellent (ICC, 0.941). DuDoTransGAN achieved the highest mean scores among unsupervised methods for artifact removal (3.87 ± 0.48), diagnostic value (3.75 ± 0.50), visual effect (3.90 ± 0.36), and detail retention (3.96 ± 0.40), together with a comparable sharpness score (3.87 ± 0.58), and the highest radiologist selection rate (45 % vs 2 %-21 %). CONCLUSION: DuDoTransGAN is an adaptable unsupervised dual-domain MAR framework that performs effectively on paired synthetic and unpaired clinical data, producing high-quality, clinically interpretable CT images in the presence of metallic implants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.IEEE journal of biomedical and health informatics · 2026
- DuF-DiT: Dual-Domain Fusion Diffusion Transformer with Latent Conditional Modeling for CT Metal Artifact Reduction.Medical engineering & physics · 2026
- Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge.ArXiv · 2026
- PDDUNet: A primal-dual deep unrolling network for CT metal artifact reduction.Journal of X-ray science and technology · 2026
- A hybrid training database and evaluation benchmark for assessing metal artifact reduction methods for X‐ray CT imagingMedical Physics · 2025
- VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal BenchmarkarXiv · 2026