Medical engineering & physics

Bone Chip Formation and Morphological Evolution in Ultrasonic Vibration-Assisted Drilling of Anisotropic Cortical Bone.

Xianzheng Zhou, Genyuan Miao, Yizhen Luo, Yimiao Chen, Jianping Bi, Qinhe Zhang

Shandong University, 17923, Jingshi Road, Jinan, P.R.China, 250061, Jinan, 250100, China. · Shandong University, 17923, Jingshi Road, Jinan, P.R.China, 250061, Jinan, Shandong, 250100, China.

Key points

From the paper's conclusion
  • These findings link anisotropic spatial constraints with ultrasonic temporal modulation and provide a mechanistic basis for interpreting bone-chip formation and informing process-parameter selection in UVAD.

Abstract

Bone-chip formation reflects material removal and may influence drilling loads, heat generation, and subsequent chip transport during bone drilling. Its morphological evolution during ultrasonic vibration-assisted drilling (UVAD) is influenced by cortical-bone anisotropy and the time-dependent kinematics of adjacent cutting edges. This study investigated UVAD of anisotropic cortical bone by establishing a local cutting-direction framework based on longitudinal, radial, and tangential material coordinates and a trajectory-based model of transient equivalent chip thickness. Near-edge in situ observation, two- and three-dimensional chip morphology characterization, and force and temperature measurements were combined to examine the effects of drilling orientation, ultrasonic amplitude, spindle speed, and feed rate. Longitudinal drilling produced wider plate-like or ribbon-like chips, whereas tangential drilling generated more elongated and curled structures. Increasing the ultrasonic amplitude from 0 to 3 μm reduced the mean projected chip width by 29.1-32.3% and the mean projected chip length by 16.4-23.7% across the three drilling orientations. The mean curling height reached its maximum at 2 μm, while more pronounced chip segmentation was observed at 3 μm. At an amplitude of 2 μm, the maximum axial force and peak near-surface temperature decreased by 25.4-26.9% and 23.7-25.6%, respectively, relative to CD. Mean chip dimensions exhibited a non-monotonic trend across the tested spindle speeds, although the spindle-speed main effect was not statistically significant. Increasing feed rate weakened the relative effect of ultrasonic trajectory modulation by increasing the baseline feed per tooth. These findings link anisotropic spatial constraints with ultrasonic temporal modulation and provide a mechanistic basis for interpreting bone-chip formation and informing process-parameter selection in UVAD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers