Modeling and Experimental Validation of Forces in Low-Frequency Vibration-Assisted Drilling Considering Bone Anisotropic Effects.
Ying Han, Jun Wang, Xianzheng Zhou, Yimiao Chen, Qinhe Zhang
Department of Cloud Computing Technology and Applications, Shandong University of Commerce and Technology, Jinan 250103, China. · Key Laboratory of Efficient and Clean Machinery Manufacturing of Ministry of Education, School of Mechanical Engineering, Shandong University, Jinan 250100, China.
Key points
From the paper's conclusion- This study focuses on modeling and experimental validation of drilling forces in low-frequency vibration-assisted bone drilling (LVAD), with explicit consideration of bone anisotropic effects.
Abstract
This study focuses on modeling and experimental validation of drilling forces in low-frequency vibration-assisted bone drilling (LVAD), with explicit consideration of bone anisotropic effects. A mechanistic force model is established by integrating contributions from the main cutting edges and chisel edge, and a direction-dependent anisotropic coefficient is introduced to characterize the anisotropic shear strength of cortical bone. The influences of feed rate, spindle speed, drill diameter, vibration amplitude, frequency, and drilling orientation on drilling forces are analyzed theoretically and experimentally. Results show that drilling forces increase with feed rate and drill diameter and decrease with spindle speed and vibration amplitude. LVAD reduces drilling forces by up to 16.52% compared with conventional drilling. Perpendicular drilling produces lower forces than oblique drilling, and forces in the yz-plane are higher than those in the xz-plane due to bone anisotropy. The proposed model is well verified by experiments, providing a theoretical basis for parameter optimization in clinical bone drilling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bone Chip Formation and Morphological Evolution in Ultrasonic Vibration-Assisted Drilling of Anisotropic Cortical Bone.Medical engineering & physics · 2026
- Force-thermal behaviors and process optimization of ultrasonic vibration-assisted bone drilling for minimally invasive orthopedic surgeryJournal of Materials Research and Technology · 2026
- Mechanistic Investigation and Performance Evaluation of Ultrasonic Bone Drilling under Longitudinal-Torsional Coupled Vibration.Medical engineering & physics · 2026
- Prediction of human bone sawing forces from bone porosity, tool geometry, and machining parameters.Journal of the mechanical behavior of biomedical materials · 2026
- Material removal mechanism of bone with laser-assisted grinding for low-damage and high-efficiency processMaterials and Manufacturing Processes · 2026
- Progressive Changes in Commercial Orthopedic Drill Bits During Repeated Drilling of Synthetic Bone: Drill-Point Geometry, Thrust Force, Feed Work, and Hole Diameter.Materials (Basel, Switzerland) · 2026