Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone During Oscillating Sawing.
Han Wang, Urara Satake, Toshiyuki Enomoto
Division of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, 2-1, Yamada-oka, Suita, Osaka, 565-0871, Japan. · Division of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, 2-1, Yamada-oka, Suita, Osaka, 565-0871, Japan. satake@mech.eng.osaka-u.ac.jp.
Key points
From the paper's conclusion- Turning-point impacts compromise the biomechanical integrity of cortical bone by reducing the load-bearing capacity of implant-relevant bone surfaces. Suppressing these transient impacts helps preserve implant-relevant bone surface integrity and may improve the stability of the bone-implant interface. These findings provide a biomechanical basis for future real-time impact monitoring and adaptive control in surgical robotics to prevent impact-induced damage.
Abstract
PURPOSE: Oscillating bone sawing is widely used in orthopedic surgery, where preserving the mechanical integrity of the prepared bone surface is essential for implant stability. However, the influence of turning-point impacts on the biomechanical integrity of the prepared bone surface remains unclear. This study aimed to quantify the effects of turning-point impacts on surface integrity and the mechanical properties of cortical bone. METHODS: Oscillating sawing experiments were performed on bovine cortical bone using conventional and optimized trajectories. Dynamic sawing forces were measured to quantify turning-point impact events. Surface damage was characterized by scanning electron microscopy and digital microscopy. Local and global mechanical properties were evaluated by flat-punch and conventional compression tests, respectively. RESULTS: The conventional trajectory generated pronounced turning-point impact forces, accompanied by extensive surface cracks and breakout defects. In contrast, the optimized trajectory significantly suppressed turning-point impact forces (p < 0.001) and preserved groove wall surface integrity. Consequently, both the local (p < 0.001) and global (p = 0.001) compressive strengths increased, whereas the elastic modulus remained unchanged. These findings indicate that turning-point impacts primarily reduce failure strength by introducing localized microstructural defects while largely preserving bulk elastic stiffness. CONCLUSION: Turning-point impacts compromise the biomechanical integrity of cortical bone by reducing the load-bearing capacity of implant-relevant bone surfaces. Suppressing these transient impacts helps preserve implant-relevant bone surface integrity and may improve the stability of the bone-implant interface. These findings provide a biomechanical basis for future real-time impact monitoring and adaptive control in surgical robotics to prevent impact-induced damage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanistic Investigation and Performance Evaluation of Ultrasonic Bone Drilling under Longitudinal-Torsional Coupled Vibration.Medical engineering & physics · 2026
- Bone Chip Formation and Morphological Evolution in Ultrasonic Vibration-Assisted Drilling of Anisotropic Cortical Bone.Medical engineering & physics · 2026
- Torsional Strength Reduction of Rabbit (Oryctolagus cuniculi) Femora is Not Significantly Different after Insertion of Cortical Screws, Locking Screws or Kirschner Wires.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Prediction of human bone sawing forces from bone porosity, tool geometry, and machining parameters.Journal of the mechanical behavior of biomedical materials · 2026
- Force-thermal behaviors and process optimization of ultrasonic vibration-assisted bone drilling for minimally invasive orthopedic surgeryJournal of Materials Research and Technology · 2026
- Material removal mechanism of bone with laser-assisted grinding for low-damage and high-efficiency processMaterials and Manufacturing Processes · 2026