Influence of Screw Diameter on the Pull-Out Resistance of Additively Manufactured Auxetic Bone Screws in Cancellous and Cortical Bone.
Ahmet Meram, Mehmet Emin Çetin, Haluk Yaka, Kemal Odev, Mustafa Özer
KTO Karatay University, Akademi, Celal Bayar Cd., Konya, Konya, --- Select One ---, 42130, Turkey. · Aerospace Engineering, Necmettin Erbakan Universitesi, Necmettin Erbakan University Koycegiz Campus, Konya, Konya, --- Select One ---, 42130, Turkey.
Key points
From the paper's conclusion- The results showed that auxetic bone screws exhibited approximately 10% higher pull-out strength compared to conventional screws.
Abstract
This study investigates the effect of screw diameter on the pull-out strength of a bone screw with a loosening-resistant auxetic structure manufactured using additive manufacturing. The variation in mechanical performance depending on screw diameter was examined experimentally and through finite element analysis in cancellous and cortical bone structures. First, screw designs with different diameters incorporating an auxetic cell structure were created in SolidWorks. The designed screws were analyzed using ANSYS Workbench finite element software, confirming that the structures exhibit a negative Poisson's ratio. The screws were manufactured from Ti6Al4V alloy using the Direct Metal Laser Sintering (DMLS) additive manufacturing process. The fabricated auxetic screws were inserted into synthetic cancellous and cortical bone (L4-L5 vertebral bone). The pull-out tests were performed under conditions conforming to the ASTM F543 standard. Force-displacement curves were obtained from the experiments, and tensile tests were also conducted to determine the mechanical strength of the screws. To evaluate the performance of the auxetic screws, identical pull-out tests were carried out on conventional bone screws. After the tests, SEM images were obtained to examine the damage mechanisms in detail. The results showed that auxetic bone screws exhibited approximately 10% higher pull-out strength compared to conventional screws. This improvement is attributed to increased surface roughness and radial expansion under tensile loading, which enhance mechanical interlocking at the bone-screw interface. Finite element analyses further indicated that the magnitude of the negative Poisson's ratio increased with increasing screw diameter, suggesting more effective mechanical behavior at larger diameters. In addition, the porous structure of the auxetic screw is expected to facilitate bone ingrowth, thereby supporting bone healing and reducing the risk of loosening. Finally, the developed auxetic bone screw has the potential to increase resistance to loosening. In addition, it may enhance biological integration with bone, which could contribute to improved surgical outcomes and greater patient comfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A auxetic metamaterial structure: analysis of shear and bending, mechanical characterization4D Printing · 2026
- A review on auxetic structures: Applications, properties, classifications, finite element analysis, manufacturing methods, and selective laser melting process parametersResults in Engineering · 2025
- Laser-based powder bed fusion additive manufacturing and mechanical characterization of 316 L stainless steel auxetic lattice structuresThe International Journal of Advanced Manufacturing Technology · 2026
- Design and evaluation of a modified arrow-head auxetic structure (pinehead) for enhanced energy absorptionSmart Materials and Structures · 2025
- A Novel Abutment Screw Head Design with an Integrated Retrieval Feature: An In Vitro Study.Dentistry journal · 2026
- Enhancement of 3D Printed Polymeric Auxetic Metamaterials Through Curved‐Member Unit Cells: Numerical Evaluation of Poisson’s Ratio and Experimental Evaluation of Tensile Strength and Impact ResistanceAdvances in Polymer Technology · 2026