IOP Conference Series: Earth and Environmental Science

Evaluating Structural Seismic Performance of PMA Cadet Barracks Using Incremental Dynamic Analysis

Henry Mikael L. Gando, Jan Nicholas S. Baldo

Key points

From the paper's conclusion
  • The findings demonstrate the applicability of PBSE for evaluating existing essential facilities and provide technical information to support seismic risk reduction and retrofit prioritization within the PMA campus.

Abstract

The Philippine Military Academy (PMA) in Baguio City is situated in a seismically active region of the Philippines. It must maintain its operational capability following major earthquakes because of its role as a national military training institution and a frontline disaster response asset. This study applies Incremental Dynamic Analysis (IDA) within the framework of Performance-Based Seismic Engineering (PBSE) to assess the seismic performance of three identical cadet barracks within PMA, namely Regis Hall, Florendo Hall, and Enrile Hall, which are represented by a single structural model. Deterministic Seismic Hazard Analysis (DSHA) was conducted to define the controlling earthquake scenarios for the site based on nearby faults and estimated site conditions (V s30 = 235 m/s). Fifteen unscaled ground-motion records were selected from the PEER NGA-West2 database using SeismoSelect according to earthquake magnitude, source-to-site distance, fault mechanism, and site characteristics. A nonlinear finite element model was developed in SeismoStruct using Mander confined concrete and Menegotto-Pinto steel constitutive models while accounting for geometric nonlinearity. The records were incrementally intensified using spectral acceleration at the fundamental period, Sa(T 1 ), as the intensity measure to generate IDA curves, and structural performance was evaluated using maximum interstory drift ratio in accordance with the Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) performance criteria of FEMA 356 for reinforced concrete walls. The median IDA results indicate that the transverse (Y) direction exhibits greater lateral resistance than the longitudinal (X) direction because of the configuration of the reinforced concrete shear walls. The findings demonstrate the applicability of PBSE for evaluating existing essential facilities and provide technical information to support seismic risk reduction and retrofit prioritization within the PMA campus.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers