Incremental dynamic analysis-based seismic fragility of an IS 13920:2016 RC frame in Zone IV: a HAZUS-MH comparison
N. Lalitha Kumari, Prahlad Prasad, Pramod Kumar, Regasa Yadeta Sembeta
Key points
From the paper's conclusion- This study performs an Incremental Dynamic Analysis (IDA)-based fragility assessment of a seven-storey RC MRF designed to IS 456:2000, IS 1893:2016, and IS 13920:2016, located in Seismic Zone IV.
Abstract
Seismic fragility data for RC moment-resisting frame (MRF) buildings designed to current Indian codes are scarce. HAZUS-MH vulnerability functions are widely used as a substitute in Indian practice. Their applicability to Indian RC construction has not been rigorously tested. This study performs an Incremental Dynamic Analysis (IDA)-based fragility assessment of a seven-storey RC MRF designed to IS 456:2000, IS 1893:2016, and IS 13920:2016, located in Seismic Zone IV. Seven PEER NGA-West2 records were scaled to ten peak ground acceleration (PGA) levels between 0.2 g and 2.0 g, giving 70 nonlinear time-history runs. Maximum inter-storey drift ratio (IDR) was used as the engineering demand parameter (EDP). Lognormal fragility parameters were fitted by Maximum Likelihood Estimation (MLE) with 90% bootstrap confidence intervals for four HAZUS-compatible damage states. Median PGA capacities come out to 0.503 g and 1.141 g for Extensive and Complete damage under the corrected HAZUS-MH C1M (Mid-Rise), High-Code classification appropriate to a 7-storey building; Slight and Moderate damage sit at intensities too low for the present IDA sampling to resolve reliably. All seven records show drift concentrating at the first storey in a soft-storey-like pattern. Against the corrected C1M benchmark, the building comes out more fragile than the generic curve at Moderate damage (ratio 0.82) and less fragile at Extensive and Complete damage (1.48 and 1.26); the 90% confidence interval lower bounds do not consistently sit above the HAZUS medians. Taken together, these results do not support a general claim that HAZUS-MH is conservative for this building, and further multi-building study would be needed before drawing any broader conclusion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Displacement-based seismic fragility assessment of a high-rise reinforced concrete buildingScientific Reports · 2025
- Efficient Estimation of Structure‐Specific Fragility Curves Using Ground Motion Clustering Within Multiple Stripe AnalysisEarthquake Engineering & Structural Dynamics · 2026
- Impact of Earthquake Hazard on Various Structures-A Case Study in Myanmar.TheScientificWorldJournal · 2026
- Evaluating Structural Seismic Performance of PMA Cadet Barracks Using Incremental Dynamic AnalysisIOP Conference Series: Earth and Environmental Science · 2026
- Seismic Fragility Analysis of Subway Station Structures Based on Shaking Table Tests and IDAEng · 2026
- Parametric Seismic Assessment of Informally Constructed Masonry‐Infilled Reinforced Concrete Frame Archetypes Considering Structural VariabilityEarthquake Spectra · 2026