Prediction of IDA Drift Ratio in Low-Rise Reinforced Concrete Structures in La Trinidad, Benguet, Philippines using Surrogate Modelling and MATLAB-Based Artificial Neural Networks
Grant Lloyd L. Lawaguey, Jan Nicholas S. Baldo, Andres Winston C. Oreta, Dexter Hansel C. Apnoyan, Emerson O. Gapuz
Key points
From the paper's conclusion- In contrast, during high-intensity extrapolation, Cornell’s physics-informed power law provided a highly conservative safety envelope (9% roof drift versus 3% actual) and enforced physical boundary consistency (EDP=0 when IM=0).
Abstract
The seismic safety of low-rise reinforced concrete buildings is a primary Disaster Risk Reduction priority in high-hazard regions in the Philippines, such as La Trinidad, Benguet. Local government units (LGUs) require rapid, municipality-wide vulnerability assessments to inform retrofitting and policy development; however, advanced evaluation methods like Incremental Dynamic Analysis (IDA) remain computationally demanding. This research was developed and compared data-driven surrogate models for predicting seismic inter-story drift demands of low-rise reinforced concrete buildings under near fault seismic hazards. A non-linear finite element model of a two-storey reinforced concrete structure, representative the local residential building stock was developed and modelled in SeismoStruct, then subjected to various earthquake ground motions to generate a comprehensive seismic response database. Three predictive models were implemented and systematically evaluated: Second-degree polynomial regression, Cornell’s physics-informed power-law model, and a MATLAB-based Multilayer Perceptron (MLP) Artificial Neural Network (ANN). To ensure physical safety and numerical stability, the surrogate models were trained on low-to-moderate shaking data and validated against high-intensity, near-collapse demands up to 0.80g. The performance of the surrogate models was systematically assessed in terms of localized fitting accuracy, extrapolation stability, and physical consistency. The neural network achieved outstanding localized precision (R=0.9527) and compressed non-linear simulation lead-times by 99.5% (from hours to milliseconds). In contrast, during high-intensity extrapolation, Cornell’s physics-informed power law provided a highly conservative safety envelope (9% roof drift versus 3% actual) and enforced physical boundary consistency (EDP=0 when IM=0). Ultimately, this study establishes a tiered, dual-surrogate framework: the ANN is recommended for rapid, municipal-scale screening, while the Power Law model is recommended for safety-critical structural auditing and reinforcement design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seismic Response Prediction of 3D Reinforcement Concrete Frames Using Machine Learning MethodsPeriodica Polytechnica Civil Engineering · 2026
- Ground motion modelling with bidirectional liquid neural network (BLiqNet)Geodata and AI. · 2026
- Efficiency-aware seismic fragility analysis of super-high arch dam using unsupervised ground motion clustering with probabilistic representationAdvanced Engineering Informatics · 2026
- A data-driven approach for rapid seismic risk prediction of RC buildingsBulletin of Earthquake Engineering · 2026
- Comparing machine learning and deep learning approaches to predicting the seismic response of slab-column connectionsScientific Reports · 2026
- Data-driven prediction of drift capacity for reinforced concrete shear walls using tree-based machine learning modelsData-Centric Engineering · 2026