Parametric Study of Corner Geometry Variations for Heat Transfer Control in Insulated FRP-Strengthened Square RC Columns under Fire

Hamidah Mohd Saman, Afifudin Habulat

Key points

From the paper's conclusion
  • The results indicate that increasing corner radius significantly reduces local heat concentration, while thicker and better-distributed insulation further delays heat penetration.

Abstract

This study examines the effect of corner geometry on heat transfer in insulated fibre-reinforced polymer (FRP)–strengthened square reinforced concrete (RC) columns exposed to fire. A finite element (FE) parametric study comprising 18 configurations was conducted to evaluate the influence of insulation thicknesses ranging from 13 to 50 mm, corner radii of 0, 15, and 30 mm, and both uniform and asymmetric insulation configurations on temperature development at the concrete surface and reinforcement. Transient heat transfer analyses were performed under ASTM E119 fire, with temperatures monitored at the FRP–concrete interface and reinforcement level. The FE model was validated against published numerical results, indicating good agreement. The results indicate that increasing corner radius significantly reduces local heat concentration, while thicker and better-distributed insulation further delays heat penetration. In contrast, sharp corners and thinner insulation accelerate temperature rise at critical regions.