Tensile Behavior of Glass Fiber Reinforced Polymer (GFRP) Bars with Different Diameters for Structural Applications
Muhammad Rafani, Tavio, Francisco José de Caso y Basalo
Key points
From the paper's conclusion- The data are intended to support design assumptions and analytical or numerical modeling of concrete members reinforced with GFRP bars.
Abstract
Glass Fiber Reinforced Polymer (GFRP) bars are used increasingly as non-corroding reinforcement in concrete members exposed to severe service environments. Because GFRP reinforcement does not yield before rupture, its tensile response becomes one of the main material inputs for flexural design, crack-width assessment, deflection calculation, and numerical modeling. This work examines the monotonic tensile behavior of commercially available E-GFRP reinforcing bars with nominal diameters D13, D16, and D19. The specimens were tested using a universal testing machine following ASTM D7205/D7205M until rupture. The reported parameters comprise ultimate tensile strength, chord elastic modulus, strain values in the linear stress range, statistical scatter, and visual failure features. The measured tensile strengths varied from 273.87 MPa to 786.57 MPa. The D13, D16, and D19 groups gave mean tensile strengths of 489.13 MPa, 436.45 MPa, and 346.23 MPa, with coefficients of variation of 54.39%, 16.87%, and 15.68%, respectively. Although the mean strength decreased as the diameter increased, this tendency is discussed as indicative rather than conclusive because the dataset is limited and the scatter is evident. In contrast, the chord modulus remained close among the specimens, ranging from 29.5 GPa to 31.8 GPa. All tested bars responded elastically up to abrupt brittle fracture involving fiber splitting and longitudinal rupture. The data are intended to support design assumptions and analytical or numerical modeling of concrete members reinforced with GFRP bars.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Immersion in a 5% H 2 SO 4 Solution on the Tensile Strength of Glass Fiber-Reinforced Polymer BarsIOP Conference Series: Earth and Environmental Science · 2026
- High-temperature tensile performance of concrete-covered GFRP bars under in-situ thermal exposureJournal of Reinforced Plastics and Composites · 2026
- Investigation of the Load-Displacement Behaviour of Concrete Beams Reinforced with GFRP Reinforcement MaterialJournal of Physics: Conference Series · 2026
- Bond behavior and design challenges in GFRP reinforced concrete beams with research directionsDiscover Applied Sciences · 2026
- Tensile Properties of CFRP–GFRP Hybrid Reinforcing Bars and Their Effects on the Structural Behavior of Concrete MembersJournal of Composites Science · 2026
- Multi-technical analysis of damage process in GFRP-bar reinforced concrete beamEngineering Structures · 2025