Bond behavior and design challenges in GFRP reinforced concrete beams with research directions
Szabolcs Szinvai, Tamás Kovács, Jiao-Long Zhang
Key points
From the paper's conclusion- The findings show that surface properties are among the most influential parameters governing bond strength, but their effects are not adequately represented by the limited surface coefficients used in current design provisions.
Abstract
Glass fiber-reinforced polymer (GFRP) bars are increasingly used as internal concrete reinforcement because of their corrosion resistance and non-magnetic properties. However, their lower stiffness, brittle behavior, diverse surface treatment options, and different bond mechanisms compared with steel bars complicate the design of anchorages, lap splices and detailing in general. This paper critically reviews the bond behavior of GFRP bars and compares the corresponding provisions of major international design guidelines. A structured literature search was conducted using the Web of Science database, from which 60 relevant publications were selected for detailed assessment. The review covers bond mechanisms and failure modes, bond stress–slip models, the effects of surface treatment, concrete properties and confinement, development and lap-splice length, bent-bar detailing, and long-term bond performance. The findings show that surface properties are among the most influential parameters governing bond strength, but their effects are not adequately represented by the limited surface coefficients used in current design provisions. Therefore existing development-length equations are generally conservative, particularly for modern GFRP products and well-confined reinforcement, although unconservative predictions may occur under certain conditions. Most guidelines rely on empirical average bond-stress concepts and do not explicitly account for non-uniform bond-stress distributions. A reason for this excessive conservatism is insufficient knowledge about the bond strength reduction due to environmental exposure, sustained and long-term loading. Research priorities are therefore identified for surface characterization, confinement, non-uniform bond models, environmental exposure, sustained loading, and bent-bar detailing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive Review of GFRP Structural Systems: Material Characteristics, Structural Behavior, Durability Performance, and Infrastructure ApplicationsEngineering Reports · 2026
- Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal ConditioningJournal of Composites Science · 2026
- Design and modelling of grouted corrugated duct connections in precast GFRP-reinforced concrete structuresEngineering Structures · 2026
- Evaluating the Splice Effect on the Flexural Performance of RC Beams Reinforced with Hybrid and GFRP RebarsInternational Journal of Concrete Structures and Materials · 2026
- Effect of surface profile on the bond strength of lap spliced GFRP bars in concrete beamsEngineering Structures · 2025
- Investigation of the Load-Displacement Behaviour of Concrete Beams Reinforced with GFRP Reinforcement MaterialJournal of Physics: Conference Series · 2026