IOP Conference Series: Earth and Environmental Science

Performance and Magnetic Characterization of Cement-Based Materials Containing Electric Arc Furnace Slag and Magnetic Fine Aggregate

An Cheng, Chia-Yun Ho, Pin-Chien Cheng, Qi-Zhen Huang, Hui-Mi Hsu, Yuan-Ho Cheng

Key points

From the paper's conclusion
  • Hardened EAFS mortars exhibited relative magnetic permeability of approximately 1.009–1.033, increasing with replacement level.

Abstract

This study evaluates magnetic fine aggregate (MFA) from Taiwan’s Heping River and electric arc furnace oxidizing slag (EAFS) as partial replacements for natural sand in mortar. At a fixed water-to-cement ratio of 0.56, replacement levels were 10%, 20%, and 30% by mass. EAFS reduced flow but increased 28-day compressive strength to 38.27 MPa; MFA reduced strength. Rapid chloride penetrability test (RCPT) charges were affected by electrical conduction and possible Joule heating, so non-steady-state migration testing was also used. The 30% EAFS mix showed the lowest migration coefficient (10.211 × 10 −12 m 2 /s). Hardened EAFS mortars exhibited relative magnetic permeability of approximately 1.009–1.033, increasing with replacement level. Magnetic permeability reflects replacement trends under laboratory conditions, although reinforcement and cover effects require further investigation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers