Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses.
Phillip Olla, Sara Shannan, Mina Maleki, Ava Travo, Mohammad Paknahad, Ava Bandi, Nina Favor
Health Services Administration, College of Health Professions, University of Detroit Mercy, Detroit, MI 48221, USA. · Department of Electrical & Computer Engineering & Computer Science, University of Detroit Mercy, Detroit, MI 48221, USA.
Key points
From the paper's conclusion- These findings demonstrate the feasibility of field-based multi-channel breath acquisition and highlight the value of variability-centered analysis.
Abstract
Portable breath-sensing platforms offer a practical approach for collecting physiological and environmental information outside controlled laboratory settings, but their interpretation is complicated by inter-individual variability and sensor-related effects. This pilot study evaluated the BreathLogix VOC Series prototype, a portable multi-sensor platform incorporating gas-sensitive, carbon-dioxide, temperature, and environmental channels, during routine collegiate athletic activities. A total of 421 breath recordings were obtained from 209 participant ID codes, including 175 pre-exercise and 246 post-exercise recordings. Continuous sensor signals were converted into aggregated sample-level features and analyzed using descriptive statistics, interquartile-range comparisons, Pearson correlation analysis, and K-means clustering. Group-level median responses remained relatively stable across exercise conditions, whereas response variability changed more noticeably. Humidity showed the largest post-exercise increase in dispersion, followed by the hydrogen- and methane-sensitive channels, while the acetone-sensitive response showed reduced variability. Correlation analysis identified strong relationships among selected channels, consistent with possible cross-sensitivity and environmental influence. Clustering revealed two overlapping sensor-derived breath-signature groups primarily separated by acetone-sensitive response; a sex difference in cluster composition was not retained when each participant was counted once. These findings demonstrate the feasibility of field-based multi-channel breath acquisition and highlight the value of variability-centered analysis. Further analytical validation, calibration assessment, and longitudinal reproducibility testing are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Human Breath Volatilome Responds to Exercise and Recovery: An Untargeted Profiling Study.Journal of breath research · 2026
- Interventional breath analysis reveals oral microbial conversion of 1,2-Propanediol into Propanal and 1-PropanolbioRxiv · 2026
- Photoacoustic technologies for exhaled-breath analysis: A systematic review of analytical performance and reporting quality.Journal of breath research · 2026
- Assessing respiratory rates and signs of air hunger using the PneumoRator sensor.medRxiv · 2026
- Advances in photoacoustic spectroscopy for human breath analysisFrontiers in Physics · 2026
- Wearable respiratory sensors for non-invasive healthcare monitoring: applications and intelligent technologiesNanoscale · 2026