Journal of Instrumentation

Development of a positron imaging unit for advanced plant research

T. Ishiwatari, Y. Nagao, T. Yabe, M. Tsuda, H.G. Kang, E. Yoshida, T. Yamaya, T. Kamiya,

Key points

From the paper's conclusion
  • These fundamental performance results demonstrate the strong potential of the compact unit for localized, high-resolution plant transport studies.

Abstract

Positron-emitting tracer imaging systems (PETIS) apply the principles of positron emission tomography to plant research, enabling non-destructive, real-time visualization of substance distribution in living plants. However, the conventional PETIS instruments using bismuth germanate (BGO) scintillator arrays and position-sensitive photomultiplier tubes have limited spatial resolution 1.6–2.1 mm full width at half maximum (FWHM), and the relatively long decay time of BGO restricts the coincidence timing resolution (CTR) and count-rate performance. In addition, the thickness of the scintillator array can introduce parallax errors due to depth-of-interaction ambiguity. To enable submillimeter-scale imaging of fine structures like leaf veins, we developed a compact, high-resolution prototype PETIS unit tailored for thin plant organs. The prototype features two face-to-face detector modules separated by 2 cm. Each module consists of a finely segmented cerium-doped gadolinium aluminium gallium garnet scintillator array (1 × 1 × 1 and 1.5 × 1.5 × 1 mm 3 crystals), a 1-mm light guide, an 8 × 8 silicon photomultiplier array, and a TOFPET2 application-specific integrated circuit. The 1-mm-thick scintillator design drastically reduces depth-of-interaction parallax errors while optimizing count-rate capability. The performance was evaluated using a 22 Na point source. The system achieved 511 keV energy resolutions of 11–13 % FWHM. Reconstructed images demonstrated spatial resolutions of 1.1–1.2 mm FWHM, significantly outperforming the conventional PETIS instruments. The CTR reached 773 ± 16 ps with an effective coincidence detection efficiency of 6.54 × 10 -5 . These fundamental performance results demonstrate the strong potential of the compact unit for localized, high-resolution plant transport studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers