Feasibility study of secondary-electron-bremsstrahlung imaging with a knife-edge slit camera for range verification in carbon-ion therapy
Michiko Tsuda, Mitsutaka Yamaguchi, Yuto Nagao, Han Gyu Kang, Takuya Yabe, Eiji Yoshida, Taiga Yamaya, Makoto Sakama,
Key points
From the paper's conclusion- These results demonstrate the feasibility of knife-edge slit SEB imaging for carbon-ion beam range verification and indicate that further improvement in detection sensitivity is required for measurements with smaller numbers of incident ions.
Abstract
Secondary-electron-bremsstrahlung (SEB) imaging has been proposed as a method for in vivo range verification in particle therapy; however, insufficient detection sensitivity remains a major limitation, particularly under low-count conditions. In this study, we developed a knife-edge slit camera and evaluated its feasibility for carbon-ion beam range verification using one-dimensional SEB profiles. The camera consisted of a tungsten knife-edge slit collimator and a 16 × 16 Ce:GAGG scintillator array coupled to an 8 × 8 SiPM array. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba using a 290 MeV/u carbon-ion beam irradiated onto a water phantom. One-dimensional SEB profiles were acquired for different beam ranges controlled by range shifters. The measured profiles shifted systematically with beam range. The profiles measured with range-shifter water-equivalent thicknesses of 0.00 and 5.27 mm were visually distinguishable. Calibration-based range estimation, evaluated by Poisson resampling of high-statistics measured profiles, yielded mean precisions of 2.76, 8.89, and 29.5 mm for 10 8 , 10 7 , and 10 6 incident carbon ions, respectively. These results demonstrate the feasibility of knife-edge slit SEB imaging for carbon-ion beam range verification and indicate that further improvement in detection sensitivity is required for measurements with smaller numbers of incident ions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Decay-time correction for dual-panel in-beam PET monitoring of carbon-ion SOBP irradiation.Physics in medicine and biology · 2026
- Feasibility study of a new type of particle tracker for beam range determination by observation of charged secondary particles emitted perpendicularly from a carbon hadrontherapy beam at energies from 140 to 430 MeV/u.Zeitschrift fur medizinische Physik · 2026
- A practical framework for routine verification of Spot Position Monitor coordinate consistency in scanned carbon-ion radiotherapy.Journal of applied clinical medical physics · 2026
- A depth-resolved single-flask 3D clonogenic platform for continuous LET-dependent radiobiological assessment in carbon-ion therapy.Physics in medicine and biology · 2026
- Technical Preparations for the First Carbon-Ion Therapy Facility in the United StatesarXiv · 2026
- Experimental feasibility study of proton therapy range verification by a digital tracking calorimeter prototype.Physics in medicine and biology · 2026